Calculate Wall Thermal Resistance (R, U-Value)

An insulated wall, ceiling or floor is almost always built from several layers — structure, insulation, finish — each contributing its own thermal resistance. The calculator below adds up these layers to give the R-value and U-value of the complete assembly, along with its heat loss in watts. A second tab does the reverse calculation: the insulation thickness needed to reach a target R-value.

Wall assembly

Type of assembly
Layers, from outside to inside

Leave a thickness at 0 to skip a layer you don't need.

Used for any layer whose material is set to "Custom".

Area and temperatures (optional)
Target R-value

E.g. many modern building codes target R ≥ 7 in roofs, R ≥ 4 in walls.

Hollow concrete block20 cmHigh-performance fibreglass insulation14 cm1.3 cmoutsideinside
Wall cross-section (non-zero layers).

Terms marked with an asterisk are defined in the glossary at the bottom of the page.

Why Part L asks for a U-value, not an R-value

Approved Document L* never asks for an R-value*. It asks for a U-value*. That single habit of the English Building Regulations explains most of the muddle on a British site. Manufacturers of mineral wool still print an R-value on the pack, because R belongs to a product of a given thickness. U belongs to the finished wall, roof or floor, surface films included. Bigger R is better. Smaller U is better. They are reciprocals only after every layer has been counted.

For a homogeneous layer, thickness e in metres and thermal conductivity* λ in W/(m·K) are enough:

R = e / λ  ·  U = 1 / Rtotal

100 mm of high-performance glass mineral wool at λ = 0.032 gives R = 0.10 / 0.032 = 3.13 m²·K/W. That is not yet the wall U. The finished U is the reciprocal of the sum of every R — block, quilt, plasterboard — plus the internal and external surface resistances Rsi and Rse. For a wall to outside air those films add about 0.17 m²·K/W; a roof with the insulation at ceiling level is closer to 0.14; a ground floor on the order of 0.17 to 0.21 depending on the finish. Skip the plasterboard and the second decimal barely moves. Skip Rsi and Rse and it does. Skip the masonry on a poorly insulated wall and the whole number is fiction.

SAP and RdSAP consume U-values. This page reports both R and U so a pack of quilt and a wall specification can be compared on the same screen.

Cavity walls, solid walls, and a one-dimensional stack

Most dwellings in Great Britain are cavity wall* construction: an outer brick leaf, a gap, an inner block or brick leaf. From the 1920s into the 1970s that gap was often empty; partial fill and wider cavities came later. A Victorian terrace is typically 9-inch solid brick. This calculator does not know which of those it is looking at. It only adds layers that have been typed in.

An unfilled cavity is not a layer of still air 50 or 70 mm thick with a handsome R. Air moves in a cavity that is open at the top, at the weep holes, at the wall ties. The conventional U of an unfilled brick-and-block cavity wall sits around 1.4 to 1.6 W/(m²·K). Injected mineral wool or beads can bring that down toward 0.5 to 0.7, if the cavity is clean and the fill is complete. A modern 150 mm full-fill cavity with a lightweight inner leaf is a different animal again.

Four layers cover a solid wall plus insulation plus plasterboard, or a block inner leaf plus partial-fill board. Wall ties, mortar joints and a rainscreen leaf belong in a calculation to BS EN ISO 6946, with the corrections that standard demands.

Linear thermal bridges this calculator omits

Heat does not only travel through the clear wall. It short-cuts at floor edges, lintels, party-wall junctions, window reveals, steel columns, and balcony slabs. A thermal bridge* is exactly where the one-dimensional picture fails. Linear bridges are reported as a ψ-value in W/(m·K); point bridges as χ in W/K.

On a 1930s terrace given internal wall insulation, the intermediate floor edge can sit around ψ = 0.4 to 0.8 W/(m·K) if the joists still bear on the cold masonry. Ten metres of that junction is 4 to 8 W/K — the same order as a poorly specified window, and none of it appears in the stacked R above. Lintel types matter just as much: a steel box lintel with no insulation at the soffit is a different bridge from a thermally broken unit.

The U on this page is a clear-wall U. It is not the wall U that goes on a SAP worksheet, and it is not the figure a PAS 2035 retrofit assessment would sign off. Junctions are left out on purpose.

Sizing a board thickness, comparing two products, checking whether 100 mm or 120 mm of PIR is needed to hit a target R: that is what the 1D sum is for. Compliance, grant work, and any calculation that claims a whole-element U need a junction catalogue (Accredited Construction Details, or a numerically modelled set) as well. Until those ψ-values are added, the number here is a centre-of-panel figure, not a building figure.

External or internal wall insulation

External wall insulation* wraps the house. Floor edges stay on the warm side, lintels too, and the masonry keeps its thermal mass inside the insulated envelope. Floor area is unchanged. The elevation changes, the pavement needs a scaffold licence, every window reveal is rebuilt, and eaves, verges and rainwater goods usually move. Costly. On a solid brick terrace with a plain front, it is often the cleaner thermal answer — provided planning, a conservation area, and the neighbour's party wall all allow it.

Internal wall insulation sits in the room. A listed façade, a rented street front the landlord will not touch, a party wall that cannot take a render system: sometimes it is the only route. A few centimetres of floor area disappear. Cold bridges remain at joist ends and at the floor edge. The existing masonry moves onto the cold side of the insulation, so a vapour control layer* on the warm side is not a nice-to-have. Without it, indoor moisture meets a wall that is now too cold, and water collects in the quilt or against the brick.

There is no hierarchy of virtue. There is a façade, a party wall, a budget, and a planning officer. EWI wins on linear bridges. IWI wins on access and on streetscape. Mixing the two on one house — EWI on the gable, IWI on the front — creates hybrid junctions that need drawing, not improvising. This calculator never sees that geometry. It only adds layers.

Fabric targets under Approved Document L

Part L speaks U. A rough conversion, once surface films are in, is R ≈ 1/U. The limiting fabric parameters for new dwellings in England (2021 edition, with later amendments) are not the same as the notional dwelling used to pass the TER. Typical numbers people actually work to:

  • New-build wall, limiting — U 0.26 W/(m²·K). The notional dwelling is nearer 0.18. Many specifications go lower still.
  • Existing wall, renovation — a common target is U 0.30 for solid wall with EWI or IWI (R around 3.3). An unfilled cavity is a different measure: fill first, if the cavity is suitable, before arguing about lining.
  • Loft, insulation at ceiling level — limiting U 0.16, which is why 270 mm of mineral wool became the stock answer. The area to buy is the loft plan, not the roof slope; for pitched coverings, the roof-area calculator is the right tool for tiles, not for quilt.
  • Ground floor — new-build limiting U 0.18; a suspended timber floor with quilt between joists and a decent edge detail can get close. A solid floor is limited by the available build-up.

Wales, Scotland and Northern Ireland publish their own technical documents; the limiting numbers are not always the same. PAS 2035 retrofit work uses targets of this kind and then checks moisture risk. This page reports R and U of the clear build-up. It does not stamp the job as compliant.

Pushing a solid wall to R = 8 with IWI means roughly 250 mm of high-performance wool inside the room — window boards rebuilt, radiators moved, floor area lost. The same extra R in a loft is a few more bags of blown wool. The last point of R is paid in habitable space on a wall, and mostly in depth on a ceiling.

Why a second layer of quilt buys less than the first

R-values add. Comfort does not, not in a straight line.

Rtotal = R1 + R2 + … + Rsi + Rse  ·  U = 1 / Rtotal

Double the thickness of one product, double R. U is the reciprocal. Going from R = 2 to R = 4 halves the heat loss: the room feels it, the bill shows it. Going from 6 to 8 trims U by a quarter (0.167 → 0.125). That last 30 mm costs as much to fit as the first — cutting, fixings, labour — and saves fewer watts.

In a loft the extra quilt is usually cheap and the area is large, so the last 50 mm is still worth doing. On a wall already at R = 5 the argument shifts. The remaining losses sit at the window reveal, the uninsulated floor, the open loft hatch — not in a further 15 mm of PIR. Two different products (wood fibre plus mineral wool, PIR plus a residual cavity) still add in R, provided each λ is the right one and the interface is continuous. A gap between boards does not add R. It can ventilate the build-up instead.

Interstitial condensation and the vapour control layer

Indoor air is warmer and, for much of the year in a British climate, wetter than the air outside. Water vapour is driven toward the cold face. If it crosses the insulation and meets a plane that is too cold — the inner face of solid brick, a poorly open roof underlay — it can condense. Lambda worsens, plaster stains, timber moves, quilt slumps.

A VCL belongs on the warm side, room side, for IWI and for rafter-level loft work. It is not a leftover sheet of damp-proof membrane from the floor slab. The useful figure is the equivalent air layer thickness sd, in metres. A low sd (0.2 m) is vapour-open. A high sd (20 m and above) is close to a barrier. A lime-hemp or breathable masonry wall is not asking for polythene; a mineral-wool lining on dense block is. Sticking a high-sd sheet onto a wall designed to dry by diffusion is as wrong as omitting the membrane on a cold IWI build-up.

Variable-sd membranes tighten in winter and open in summer, which helps the wall dry inwards. They do not excuse unsealed service penetrations, unlapped joints, or a socket chasing that punches through to the cold side.

Ventilation is not a bolt-on to the VCL. Cooking, showers, four people breathing: the moisture is made inside. Extract fans, trickle vents, MVHR. The membrane holds vapour back. It does not throw it out. Insulating without a moisture plan simply parks the problem in the wall, which is why PAS 2035 treats ventilation and fabric as one assessment, not two shopping lists.

ECO4, GBIS and what a funded measure actually checks

In Great Britain the scheme names move; the idea does not. ECO4 is the energy-company obligation: suppliers fund measures in eligible households. The Great British Insulation Scheme is the lighter cousin, aimed at loft, cavity and easier fabric work. Local authority top-ups exist. VAT on many energy-saving materials is reduced. Eligibility, tenure rules and the list of qualifying measures change. gov.uk is the source, not last year's leaflet, and not a grant page written for another country.

A great deal of funded work sits behind PAS 2035: whole-house assessment, moisture, ventilation, not a roll of quilt on its own. TrustMark registration, an appropriate installer, a target U, sometimes a post-install check. This calculator sizes the wall. It does not fill in the form, and an R of 4 obtained here does not “pass” a measure.

A wall measure that leaves the loft empty and the hatch unsealed can move an EPC by one band and leave the draughts where they were. Funded programmes increasingly want more than one element treated. The calculator only says how hard the clear wall resists heat flow.

Worked example: a 200 mm concrete-block wall to R = 4

A 1980s house, 200 mm hollow concrete block, λ = 1.15 W/(m·K) — the figure on this page, not a rounded “about 1”. Target R = 4 with IWI, wall to outside air (Rsi + Rse = 0.17).

  1. R of the block = 0.20 / 1.15 ≈ 0.174. With surface films: 0.174 + 0.17 ≈ 0.34 m²·K/W. A radiator still heating the street.
  2. Insulation must supply 4.00 − 0.34 = 3.66 m²·K/W.
  3. High-performance glass wool, λ = 0.032: e = 3.66 × 0.032 = 0.117 m, call it 120 mm. EPS at 0.038 wants about 140 mm. PUR at 0.024, nearer 90 mm.
  4. VCL on the room side, studs if the insulation is not a rigid board, plasterboard to finish. The board adds almost no R (13 mm / 0.25 ≈ 0.05). It is not how the target of 4 is reached.

e = Rinsulation × λ  →  3.66 × 0.032 = 0.117 m

The second tab on this page is that multiplication. 120 mm of high-performance wool on this block, plus plasterboard, is the demonstration stack in the form (200 + 120 + 13 mm, a shade over 4). Off-the-shelf boards come in 100, 120, 140 mm: the next size up is the one that gets ordered, and then the reveals, the membrane return and the socket boxes still have to be detailed. The calculated R assumes a continuous layer, with no gap at the head of the lining.

Declared lambda and the wall as built

The λ on the datasheet is a dry laboratory figure, often at 10 °C. Mineral wool, cellulose and wood fibre take up moisture and then conduct more; XPS much less so. A declared 0.032 can sit nearer 0.040 once damp, and the 120 mm just sized no longer delivers R = 3.75. Declared and design values are the figures to type in, not the slogan on the bag.

Workmanship moves the result again. Boards with open joints, wool crammed into a stud too narrow, blown loft insulation of uneven depth: the real R falls. The calculator assumes constant thickness and constant λ. It does not see settlement, and it does not see the repeating bridge of timber studs (λ ≈ 0.13) or steel channels (far worse). A lining on metal bars with no thermal break pays in U even when the wool between the bars is 0.032.

Still air, and cavities that breathe

A 20 mm unventilated gap behind a plasterboard lining does insulate a little — R of about 0.15 to 0.18 in a vertical wall, and that is the ceiling. 100 mm of air is not five times better: convection starts and R flattens. A ventilated cavity — a rain-screen void, a tiled roof above a breather membrane, the residual cavity in a partial-fill wall that is open at the weepholes — barely insulates at all. Typed in as if it were a layer of wool, it makes the U look excellent on paper and ordinary in the room.

Still air is an insulator only when it is thin, closed, and out of the wind. The form has no material called “air”. Applying the conductivity of still air (about 0.026) to a 100 mm gap would invent an R of 3.8. That is not how air behaves in a real wall.

Decrement delay is not a U-value

R and U are steady-state numbers — January, 20 °C in, 0 °C out, day and night. Decrement delay is the lag of a summer heat wave through the wall. Heavy masonry, thick wood fibre, a solid wall insulated from the outside: the indoor peak arrives in the evening, sometimes at night. A thin PIR board can have a handsome U and almost no lag. Overheating assessments (and the current Part O in England) care about that, not about wall U alone.

Summer comfort is not chosen from the R on this page. Thermal capacity, shading and night ventilation weigh as much. IWI that cuts the masonry off from the room removes the mass that used to buffer the afternoon — one reason EWI is often preferred on solid-walled houses.

Airtightness is a separate job

Tape missed at a socket, quilt stuffed around a soil pipe and left open to the loft, a loft hatch with no seal: air moves. That leak is in none of the R-values added above. Part L sets an air-permeability limit; a blower-door test sees it, this 1D sum does not. In existing houses the leaks cluster at floor-wall junctions, around frames, at loft hatches and at suspended timber floors.

Insulating and sealing are two trades. Do one and skip the other, and the calculated U is a brochure U. The air that leaks also carries vapour, and it bypasses the most careful VCL. An R of 4 on paper, an unsealed loft hatch, and in a gale the dwelling still behaves like an R of 2.

Glossary

R-value
Thermal resistance of a layer, in m²·K/W. Higher R means the layer holds heat back more effectively. For a homogeneous layer, R = thickness / λ.
U-value
Heat flow through one square metre of the finished element for a one-kelvin temperature difference, in W/(m²·K). U is the reciprocal of the total resistance (layers plus surface films). Lower U means less heat loss. This is the figure Building Regulations ask for.
Lambda (λ)
Thermal conductivity of the material, in W/(m·K). Common insulation sits around 0.022 to 0.050; dense concrete block around 1.1 to 1.3; brick around 0.8. Lower λ means more insulation at a given thickness.
Vapour control layer (VCL)
A membrane on the warm side of the insulation that slows the passage of water vapour. Not every sheet is polythene: the right sd depends on the wall. A VCL holds vapour back; it does not ventilate the room.
Cavity wall
The default British masonry wall: two leaves with a gap between them. The cavity may be empty, partially filled or fully filled. An unfilled cavity is not equivalent to a thick layer of still air.
Thermal bridge
A path where heat bypasses the insulation — lintel, floor edge, window reveal, party wall. Reported as a linear ψ-value (W/(m·K)) or a point χ-value (W/K). This calculator does not include it.
Part L
Approved Document L of the Building Regulations in England, covering the conservation of fuel and power. Wales, Scotland and Northern Ireland publish their own equivalent documents. Part L specifies U-values, not R-values on a bag of wool.
EWI
External wall insulation: a system fixed to the outside of the masonry, then rendered or clad. Floor edges stay warm; the elevation changes; linear bridges usually fall.