Wind Turbine Power & Annual Output Calculator

The power a wind turbine captures depends first on the swept area of its blades — so on the square of the rotor diameter — and above all on the cube of the wind speed: double the wind, and the power available multiplies by eight. That's what makes picking the right site as decisive as the size of the machine.

No turbine captures all of that wind: the Betz limit caps at 16/27 (≈ 59.3 %) the theoretical fraction of kinetic energy a rotor can extract, and mechanical, electrical and conversion losses reduce that further in practice.

Annual output isn't the average-speed power read straight off, nor hours times power on a simple ratio: the wind varies, and the turbine caps its output past a rated wind speed. This page uses the industry-standard method — rated power × hours in the year × capacity factor — to stay within real-world ranges (24% to 28% onshore, 40% to 45% offshore, in Britain — see the calculation section).

Turbine and wind characteristics

The turbine

Common utility-scale onshore turbines: 90 to 150 m. Small domestic turbines: 2 to 10 m.

Fraction of the wind's energy captured by the blades. Capped by the Betz limit (16/27 ≈ 0.593); real machines run around 0.35 to 0.45.

Drivetrain, generator, inverter and transformer combined.

Speed at which the turbine reaches rated power (pitch control kicks in). 11 to 15 m/s for today's utility-scale machines.

The wind

Annual average speed at hub height. A good onshore site: 6 to 8 m/s.

1.225 kg/m³ at sea level at 15 °C; lower at altitude.

Share of the year the output is equivalent to running flat out at rated power. Already bakes in wind variability, downtime and pitch control. 24% to 28% onshore, 40% to 45% offshore, in Britain.

D = 90 mv = 7.0 m/s
Principle diagram (example values). The rotor sweeps a disc of area A = π(D/2)²; the diagram redraws with the entered values after the calculation.

Wind-engineering terms with an asterisk have a short definition in the glossary.

The Betz limit: why no rotor can exceed 59.3%

A wind turbine sits in a stream of air and slows it down. Slow it too much, and the air piles up in front of the rotor and goes around. Slow it not at all, and nothing was extracted. There is a sweet spot, and Albert Betz found it in 1920.

The limit is 16/27 of the wind’s kinetic energy — about 59.3%. It happens when the wake speed is one-third of the upstream speed. No blade shape, no carbon fibre, no clever pitch control gets past that fraction. It is a mass-flow argument, not a materials argument.

Cp, max = 16 / 27 ≈ 0.593

P = ½ · ρ · A · Cp · η · v³

Real machines run a power coefficient* Cp around 0.35 to 0.45 in everyday winds, with peak Cp on a good curve touching 0.45 to 0.50. The gap to 0.593 is drag, tip losses, the hub, and the fact that a rotor cannot impose the ideal slowdown at every radius at once. Type 0.59 into this form and the page will do the arithmetic. The machine will not.

The Betz limit is a ceiling on the rotor, not a promise. A Cp of 0.40 already describes a serious turbine. Treat 0.593 as the physics, not the spec sheet.

Onshore versus offshore wind

Power scales with the cube of wind speed. A modest difference in metres per second is a large difference in megawatt-hours. That is the whole offshore argument, before anyone mentions a jack-up barge.

  • Onshore. Average wind at 50 m is often 5 to 7 m/s on a decent site. A 2 MW turbine then makes roughly 4 to 6 GWh a year (capacity factor around 23% to 28%).
  • Offshore. Average 8 to 11 m/s, and the wind is less gusty. An 8 MW machine can generate 25 to 35 GWh a year (capacity factor around 40% to 50%).

Double the wind speed and the power, in the cubic bit of the curve, multiplies by eight. Offshore is expensive to install and to keep. It is also where the wind actually is.

Type 7 m/s and then 9 m/s on the same 90 m rotor and watch the annual figure jump. That jump is why a Scottish hill and a Midlands field are not the same project.

A real turbine's power curve

The formula P ∝ v³ is the physics in the middle of the curve. A real turbine has four acts, and two of them produce nothing.

  • Cut-in — typically 3 to 4 m/s. Below that, bearings and generators eat more than the wind gives. Output is zero.
  • Cubic rise — from cut-in up to rated speed (often 12 to 15 m/s). Power climbs roughly with the cube, which is what this page models at the average speed typed in.
  • Rated plateau — the generator and the mechanical design cap the output. Wind can keep rising; power does not. Pitch control spills the extra.
  • Cut-out — around 25 to 30 m/s the turbine shuts down (pitch to feather, brake) so the structure survives. Production ceases until the gale passes.

A site whose average is 7 m/s spends hours below cut-in and hours on the plateau — which is exactly why annual output on this page no longer comes from the power at that average speed alone. It comes from the power at the rated wind speed entered above, multiplied by a capacity factor that already carries the plateau, the calm hours and the gales in one honest percentage.

Get the rated speed wrong and the estimate drifts either way: too low understates rated power, too high overstates it. 11 to 15 m/s covers most of today's utility-scale fleet; small domestic turbines often rate lower, around 10 to 12 m/s.

Why a capacity factor beats a theoretical fudge

Wind is not a constant 7 m/s with a polite ripple. It follows a statistical distribution. The Weibull* distribution is the workhorse for describing how often each speed occurs at a site.

  • The shape factor k is the dispersion. k ≈ 2 is close to a Rayleigh distribution (quite variable winds, common inland). k > 2 means more regular winds — typical offshore.
  • The scale factor A sets the magnitude (mean ≈ A × Γ(1 + 1/k)).

One tempting shortcut is to scale the power at mean wind speed by a theoretical factor pulled from that distribution — about 1.91 for a Rayleigh regime. The catch: that factor assumes power keeps climbing with the cube well past rated speed, which no real turbine does — pitch control caps it long before. The result inflates fast, with an implied capacity factor that can brush 50% even on an ordinary site. Asking directly for a measured or typical capacity factor sidesteps the whole problem: it already prices in the plateau, the downtime and the real variability, without a power curve ever needing to be modelled.

A 0.5 m/s slip in the mean speed field above matters less for annual output now that the capacity factor carries most of the uncertainty — better to anchor that figure on data already measured for the site, or on the ranges below, than on a default.

Capacity factors onshore and offshore

Capacity factor* is actual energy over the year, divided by rated power × 8,760 hours — exactly the field asked for above. It is not a moral score. It is a wind-resource score, plus a bit of availability.

  • Onshore in a temperate climate: 24% to 28% as a long-run average (from around 18% on a mediocre inland site to 30% on an exposed northern one). Modern UK hill sites often sit in the high twenties; a sheltered Midlands field will not.
  • Offshore: 40% to 45% is a fair planning band for the current generation of North Sea machines, with some newer farms quoting higher.

Put those next to solar PV (12% to 16%) and nuclear (70% to 80%) and the reason wind needs a grid that can cope with a quiet week is obvious. A 28% onshore factor on a 2 MW turbine is about 4.9 GWh/year. The same 2 MW of solar, at 14%, is 2.5 GWh. Different machines, different years. The nuclear plant output page uses the same capacity-factor definition on a different fuel.

Hub height and vertical wind shear

Near the ground the wind is dragged by trees, buildings and the land itself. Higher up, it speeds up. The usual engineering shortcut is a power law:

V(z) = V(z0) × (z / z0)α

α, the shear exponent, runs from about 0.10 over the sea to 0.30 over dense forest or a town. Raise the hub from 80 m to 120 m and the average speed can rise 10% to 20% — and annual output 30% to 70%, because of the cube. That is why modern turbines sit on 150 m towers, and why a 10 m garden mast is not “the same wind, smaller”.

This page asks for speed at hub height. If the anemometer was on a 10 m pole, that number should not be pasted in for a 90 m rotor. Shear it first, or a farm is sized on a hedge-height breeze.

Small domestic wind turbines

A 5 kW turbine on a mast looks, in a brochure, like a way off the electricity bill. In most of Britain it is not. Average wind at 10 m is below 5 m/s across much of the country, and power goes as the cube of a number that is already too small.

  • Planning is the first wall. In England a standalone turbine is rarely permitted development; once the tip height gets past a modest mast the project is in a full application, with noise, shadow flicker, and a setback that is often greater than the height of the machine.
  • Neighbours hear it. A small turbine at 10 m is closer to bedrooms than a 90 m machine is to the next village.
  • Installed cost is high — think £8,000 to £15,000 per kW, not the per-kW figures on a utility-scale farm — and the old feed-in tariff is gone.

Small wind earns its keep on a very windy site (an Atlantic headland, an exposed farm ridge) with a well-sized self-consumption setup. A suburban garden in Berkshire is not that site. Run this page at 4 m/s, 5 m diameter, Cp 0.30, and look at the kWh before a mast is ordered.

Wake losses in a wind farm

One turbine in clean air is the calculation above. A row of them is not a row of independent machines. The downwind units sit in a slower, more turbulent wake.

  • Wake loss — 10% to 30% on a downwind machine, depending on spacing and whether they were lined up on the prevailing wind like a firing squad.
  • Farm-level diversity — the farm’s peak is lower than the sum of nameplates. A diversity factor of 0.85 to 0.95 is typical on a large site.
  • Layout rule of thumb — 5 to 10 rotor diameters downwind, 3 to 5 diameters across the wind, to keep wake losses from eating the business case.

This calculator is a single rotor. Multiply by N and the result is an upper bound, not a farm yield. A well-spaced offshore layout with a prevailing south-westerly can sit at the kind end of that 10% to 30%. A cramped ridge with the wind along the row will not.

Wind versus solar on the same site

Same field, two technologies. The choice is not a vibe. It is energy per kilowatt installed, when that energy arrives, and what the land and the grid connection will wear.

  • Annual energy per kW. A 2 MW wind turbine produces roughly 2.5 to 3 times more energy per kW installed than solar PV on the same temperate site (wind capacity factor ~25% versus solar ~13%).
  • When it happens. Wind leans into winter and the night. Solar peaks in summer at midday. They cover each other’s holes, which is why a hybrid with one grid connection is not a gimmick.
  • Footprint. A turbine’s concrete pad is small; the setback and the tip height are not. Solar wants hectares, but it stays low.
  • Civils and connection. Wind wants foundations and a road that can take a blade. Solar wants a flat-ish field and a lot of cable.

On many GB sites the boring answer is both, sharing the transformer. If the mean wind at hub height is 5 m/s and the roof already faces south, buy the panels. The cube of 5 is not a friend. The solar panel output calculator will put a number on that roof.

North Sea offshore wind

The UK’s offshore fleet lives, overwhelmingly, in the North Sea: Hornsea, Dogger Bank, East Anglia, the clusters off the Humber. Shallower water than the Atlantic west coast, a grid that already pointed at Yorkshire and East Anglia, and a wind resource that sits in that 8 to 11 m/s band. Dogger Bank, once fully built, is in the 3 GW class. Hornsea One was already a world-scale farm when it opened.

A 12 MW to 15 MW turbine with a 200 m-class rotor is now a normal order, not a concept drawing. Type 220 m into this form with Cp 0.40, a rated speed around 13 m/s and a capacity factor of 45% (steadier than inland, and it shows), and the reason a single machine can print tens of gigawatt-hours a year is on the results card. The annual figure is the easy part. The hard part is the export cable, the jack-up, and a construction weather window in a sea that does not care about a commercial operation date.

The physics on this page is the same physics as a 10 m farm turbine. Diameter squared, speed cubed, Betz in the way. Offshore is just a bigger D and a bigger v.

Contracts for Difference

Utility-scale wind in Britain is not paid the day-ahead price and left to hope. It is, mostly, a Contract for Difference*: a 15-year, inflation-linked strike price, settled against a market reference. If the market is below the strike, Low Carbon Contracts Company pays the difference. If the market is above, the generator pays back. The CfD is why a farm can raise several billion against a wind resource and a power curve.

Allocation Rounds set the strike. Some rounds have cleared offshore wind at prices that looked, at the time, almost too cheap; later rounds have had to pay more when steel, rates and supply chains moved. The strike price is not needed to use this calculator. It is needed to decide whether the MWh this page prints is a business.

The kWh are physics. The £/MWh is a contract. Run the physics first. A 24% capacity factor on a poor onshore site will not be rescued by a clever CfD.

English planning and a small turbine

England’s planning system has, since 2015, been a cold house for onshore wind. The written ministerial statement that effectively required community backing and a local-plan allocation is the reason so many good 5 to 7 m/s ridges never grew a turbine. Scotland’s system is a different climate; Wales sits in between. The 2024–25 relaxations in England are real, but they are not a free-for-all.

For a householder, permitted development for a standalone turbine is extremely tight. A building-mounted machine has its own, equally tight, limits (height above the ridge, noise, a listed building). MCS* certification is what a Smart Export Guarantee payment needs — and even then the export tariff on a poorly sited 5 kW machine will not pay the mast.

Use this page to kill bad sites early. If 4.5 m/s at hub height and a 3.5 m rotor print a few hundred kWh a year, planning is not the problem. The wind is.

Glossary

Power coefficient Cp
The fraction of the wind’s kinetic energy that the rotor extracts. The Betz limit is 16/27 ≈ 0.593. Working turbines sit around 0.35 to 0.45 in everyday winds. This page multiplies Cp by a separate drivetrain efficiency η.
Weibull distribution
The usual statistical model for how often each wind speed occurs at a site. Shape factor k ≈ 2 is a Rayleigh distribution (the default energy pattern factor 1.91). Higher k means steadier wind, typical offshore.
Capacity factor
Actual energy sent out in a year, divided by rated power × 8,760 hours. Typical GB onshore wind sits around 24% to 28%; offshore around 40% to 45%. It is a resource score, not a quality badge.
Contract for Difference (CfD)
The main GB support for utility-scale wind: a long, inflation-linked strike price settled against a market reference. Below the strike, a top-up is paid; above it, the generator pays back. It does not change the physics on this page.
MCS
Microgeneration Certification Scheme: the UK quality mark an installer and product must both hold before a small wind or solar system can qualify for the Smart Export Guarantee.