EN

Oil & Gas Energy Equivalent Calculator (kWh, CO2)

A litre of diesel, a litre of petrol and a cubic metre of natural gas don't hold the same energy: their calorific value — the energy released when a unit of the fuel is burned — varies with its chemical make-up. This calculator converts a quantity into kilowatt-hours, into tonnes of oil equivalent (toe, the reference unit for comparing any form of energy) and, when the product is actually burned, into CO2 emissions.

Crude oil isn't combustible as such: it's refined into fuels (diesel, petrol, kerosene…) before any energy use. This page therefore gives its energy equivalent, but no direct CO2 factor — that depends on the refined product obtained and on how it's subsequently burned.

Product and quantity

The quantity to convert

Crude oil, diesel, petrol and LPG are entered in litres; natural gas in m³.

In litres, or in m³ for natural gas — see the product chosen above.

Crude oil9.89 kWh/litreDiesel10.72 kWh/litrePetrol9.10 kWh/litreNatural gas11.20 kWh/m³LPG (motor fuel)7.13 kWh/litre
Energy content per usual unit of the five products (orders of magnitude). Units differ by product — an indicative comparison.

Fuel terms followed by an asterisk are defined in the glossary that closes the article.

The tonne of oil equivalent (toe)

A cubic metre of gas, a litre of diesel and a kilowatt-hour of electricity do not look comparable. The tonne of oil equivalent* is the convention that lets a statistician add them up. It is a unit of energy, not a barrel in a tank.

  • 1 toe = 41.868 GJ = 11,630 kWh. That is the IEA convention this page uses.
  • The number is the average calorific value of a tonne of crude, about 42 GJ/t, rounded into a yardstick.
  • National energy balances — DUKES in the UK — and IEA tables all talk toe (and Mtoe), letting gas, oil, coal, electricity and biomass sit on one line.

toe = energy (kWh) ÷ 11,630

Type 1,000 litres of diesel and a toe figure appears that can sit next to a gas bill or a coal delivery. The diesel is not “a tonne of crude”. The energy released is that fraction of the yardstick. Without toe, every fuel keeps its own unit and the comparison never starts.

Lower and higher heating value, and how UK gas is billed

Burn a hydrocarbon and water is made. Whether the latent heat in that water is counted is the whole LHV/HHV split.

  • Higher heating value (HHV, gross calorific value) — the heat released if the water is condensed and the latent heat is recovered.
  • Lower heating value (LHV, net calorific value) — the heat released if the water leaves as vapour, which is what most boilers and engines actually do.

For natural gas the gap is about 10%. This page’s 11.20 kWh per cubic metre is an HHV* figure, and that is the honest match to a British gas bill. UK suppliers bill in kilowatt-hours on the gross calorific value. A condensing boiler can claw back some of that latent heat; an older non-condensing boiler cannot, and its useful heat sits nearer LHV.

Continental practice often quotes LHV on industrial contracts. US and Canadian bills are HHV, like the UK. Mixing the two is how a “cheap” cubic metre becomes a 10% error. Comparing a UK kWh on the bill with an LHV boiler efficiency mixes yardsticks.

Why crude oil has no CO2 factor

Crude is not what goes in a tank. A refinery turns it into petrol, diesel, jet fuel, fuel oil, naphtha, LPG and a stack of other cuts. Each cut has its own carbon content, and therefore its own CO2 factor. A single “crude CO2” number would pretend the barrel was burned as a barrel.

That is why this calculator prints energy for crude and a dash for combustion CO2. The carbon shows up when the product is named.

  • Refining strips sulphur and metals and splits light fractions from heavy ones.
  • Light products (petrol, LPG) have a higher hydrogen-to-carbon ratio, and emit a little less CO2 per unit of energy than heavy fuel oil.

The emission factors on the diesel, petrol, gas and LPG lines are the ones for a tank or a boiler. Crude’s job on this page is the energy equivalent, nothing else.

Combustion emissions versus life-cycle emissions

The CO2 on a litre of diesel can be counted two ways, and they are not interchangeable.

  • Combustion* (tailpipe, scope 1). What leaves the exhaust when the product is burned. This page’s diesel factor is 2.51 kg CO2 per litre; petrol 2.28; LPG 1.51; natural gas 2.30 kg per cubic metre. Those are the combustion numbers.
  • Life-cycle (well-to-wheel). Add extraction, shipping, refining and filling-station distribution. The total typically sits 15% to 30% higher, depending on the crude and the route.

Regulations and fuel-duty debates usually quote combustion. A proper carbon footprint (scope 3, a company’s SECR report, a product LCA) wants the life cycle, otherwise the carbon has only been moved upstream. 2.51 kg/L of diesel is not “wrong” if it is labelled combustion. It is wrong if it is labelled well-to-wheel.

The CO2 figures on this page are combustion only. They are not a life-cycle footprint, and crude oil has no combustion factor here because crude is not burned as crude.

API gravity and crude density

Density is quoted in degrees API*. It is not a trivia number. It decides how much petrol versus heavy residue a barrel will yield, and how hard the refinery has to work.

  • Light crude (API > 35) — North Sea Brent, US WTI. More petrol, naphtha and diesel, fewer heavy residues. Better yield of the products that pay.
  • Heavy crude (API < 25) — Orinoco, oil sands. Rich in heavy fractions, hungry for cracking and hydrotreating, stingy on light products.

Two crudes with the same energy content can therefore have different product slates and different emission factors once refined. A dense barrel is more kilograms, hence more carbon, before anyone starts the FCC unit. This page’s crude line uses an average density around 0.85 kg/L. A heavy barrel is not that average.

Barrels: the unit the oil market prices

The barrel* (bbl) is how the market talks. It is 42 US gallons, which is 158.9873 litres. Prices on the screen are dollars per barrel, not pounds per tonne. Statisticians publish tonnes; traders bid barrels. Density is needed to hop between them.

volume (bbl) = mass (t) × 1,000 / (density × 158.9873)

At a typical 0.845 (about 36 °API), one tonne is roughly 7.4 barrels. Brent-like light crude, a little less dense, sits nearer 7.5. That conversion is how a DUKES table in tonnes becomes a price in dollars, and how 1,000 litres on this page become about 6.3 barrels.

The arithmetic does not care about the name on the cargo. The density does.

Diesel, petrol and LPG carbon on equal energy

Same journey, three fuels. Per litre they look different because a litre is not the same amount of energy. Per kilowatt-hour the gap shrinks.

  • Diesel — 2.51 kg CO2 per litre at 10.72 kWh/L, about 234 g CO2/kWh.
  • Petrol — 2.28 kg/L at 9.10 kWh/L, about 251 g CO2/kWh.
  • LPG — 1.51 kg/L at 7.13 kWh/L, about 212 g CO2/kWh.

On equal energy, LPG is the lightest of the three, thanks to a friendlier hydrogen-to-carbon ratio. Diesel beats petrol per kWh because a litre of diesel holds more energy, even though it holds more carbon too. The gaps are real and they are small next to the jump to a heat pump or a battery. Switching to LPG is not a climate strategy. It is a few percent on this page’s combustion line.

From a barrel of crude to refinery yields

A barrel (159 litres) does not become 159 litres of petrol. It becomes a slate. A complex refinery with catalytic cracking typically lands somewhere like this:

  • Petrol — 30% to 40% of crude volume.
  • Diesel — 25% to 35%.
  • Kerosene (jet) — 5% to 10%.
  • Heavy fuel oil — 10% to 20%, squeezed down by cracking.
  • LPG, naphtha, bitumen — the rest, 5% to 15%.

Finished-product volume is often 2% to 5% more than crude volume (a volume gain); mass is conserved, give or take a puff of fuel gas. Simple distillation makes more residue. Deep conversion makes more diesel and petrol. The configuration, not the logo on the gate, decides the slate that can be sold.

How a UK gas bill turns cubic metres into kWh

The bill is not in cubic metres. It is in kilowatt-hours, and the conversion is a small ritual Ofgem expects every supplier to perform the same way.

kWh = m³ × calorific value (MJ/m³) × 1.02264 ÷ 3.6

The 1.02264 is a volume-correction factor (temperature and pressure, to a standard condition). The calorific value is a metric, gross figure, typically around 39 MJ/m³ on the GB network, and it moves a little by region and by day. Divide by 3.6 because 1 kWh = 3.6 MJ. That is HHV billing, which is why this page’s 11.20 kWh/m³ sits in the same world as the bill and not in the LHV world of an old boiler leaflet.

Cubic metres from a meter reading, typed into this form, should land close to the kWh on the bill — close, not identical, because the local CV is not exactly 11.20. A 10% LHV/HHV mix-up is a much bigger error than a 39-versus-40 MJ/m³ wobble.

Brent: the North Sea barrel the market prices

Brent is not a museum label. Dated Brent — a cargo of North Sea crude for prompt loading — remains the marker against which a huge share of the world’s oil is priced, even though UK production is a shadow of the 1990s. The BFOE basket (Brent, Forties, Oseberg, Ekofisk) is what underpins the contract. Forties and the Norwegian grades keep the volume honest as Brent field itself declines.

A Brent-like barrel is light, around 38 °API, and the 7.3 bbl/t rule of thumb is in the right neighbourhood. When a newspaper says “oil is at $80”, it almost always means this marker, in dollars, not a tonne of Forties at Sullom Voe in pounds. Convert with the density, then with the FX rate, if a UK cost is needed.

The energy in 159 litres of Brent-like crude is what this page’s crude line is for. The dollar price is a different calculator. The petrol on a British forecourt is a refined cut, not a Brent cargo poured into a Peugeot.

DUKES, toe and the UK energy balance

The Digest of UK Energy Statistics (DUKES) is the official energy balance. Oil, gas, coal, electricity, bioenergy and heat sit in the same tables because they have been converted to toe (or to kWh, which this page also prints). 11,630 kWh per toe is the bridge.

A household gas bill of 12,000 kWh is about 1.03 toe. A thousand litres of diesel is about 0.92 toe. Adding them is the whole point of the unit. Comparing a “kWh of gas” on the bill with a “kWh of electricity” without saying whether the gas is HHV, and without saying whether the electricity is delivered or primary, is how energy-balance rows get misread.

This page converts a quantity of a named fuel. It does not apply a power-station efficiency to electricity, and it does not turn a kWh of electricity into a toe of primary energy. DUKES does that extra step in some tables. The 11,630 factor here is the fuel’s own energy, not a primary-energy equivalent.

Glossary

Tonne of oil equivalent (toe)
A conventional unit of energy: 1 toe = 41.868 GJ = 11,630 kWh (IEA). It is the average calorific value of a tonne of crude, used to add gas, oil, coal and electricity in a national balance such as DUKES.
HHV and LHV
Higher (gross) and lower (net) heating value. HHV counts the latent heat of the water produced in combustion; LHV does not. UK gas is billed on HHV. Most boilers and engines deliver closer to LHV unless they condense.
API gravity
A scale for crude density. Higher API means lighter crude (more petrol and diesel per barrel). Brent sits around 38 °API. This page’s crude line uses an average density near 0.85 kg/L.
Barrel (bbl)
42 US gallons, 158.9873 litres. The unit oil is priced in. Tonnes convert to barrels only with a density: about 7.4 bbl/t for a typical 36 °API crude, nearer 7.5 for lighter Brent-like grades.
Combustion CO2
Carbon dioxide from burning the named product, at the tailpipe or the boiler. Not a well-to-wheel life-cycle figure, which is typically 15% to 30% higher. Crude has no combustion factor here because crude is not burned as crude.

Related calculators