Section Modulus Calculator (Beam Bending)
The section modulus W sums up how well a cross-section resists bending: the larger it is, the less stress builds up for a given bending moment. It combines two geometric quantities — the second moment of area I (how the material is spread around the neutral axis) and the distance v from that axis to the most stressed fibre, at the surface of the part.
Pick the shape, enter the dimensions: the calculator returns I, v and W = I / v — the value then used to work out the bending stress σ = M / W for a given bending moment M.
The section
Section properties named with an asterisk are explained in the glossary.
Section modulus versus second moment of area: what the ratio I/v is really for
Two geometric numbers, two jobs. Both are called “inertia” in loose speech, and the units do not sort the mix-up.
The second moment of area* I, in m⁴, measures how the cross-section is spread about the neutral axis. Deflection of a beam goes as 1/(E I): double I, half the sag, same load, same span. Bending stress* is a different question. The fibre at distance y from the neutral axis sees σ = M y / I. The worst fibre is the farthest one, the extreme fibre* at y = v. Dividing I by that distance produces the elastic section modulus* W, in m³. The page reports both, plus v.
W = I / v · σmax = M / W
I is the deflection quantity. W, multiplied by the yield strength, gives the moment the extreme fibre can carry before it yields. A linear scale factor k multiplies every length, including v, by k. I is multiplied by k⁴ and W by k³. On a rectangle, I = b h³ / 12 and W = b h² / 6. Doubling h multiplies I by eight and W by four, while doubling b only doubles both.
From W to bending stress: σ = M/W
Once a bending moment M is known, the extreme-fibre stress is a division.
σmax = M / W
- σmax — MPa or N/mm², the same number. Extreme fibre, the one at v.
- M — N·m if W is in m³, N·mm if W is in mm³. Mixed prefixes are off by a billion.
- W — m³, cm³ or mm³, matching M.
Sizing runs the inequality the other way. An allowable stress is taken from the material (yield divided by a factor, or a code value with its own γM), and the section has to satisfy W ≥ M / σallow. The catalogue supplies the first section whose tabulated W clears that number. Catalogue values already include the fillets and the real root radii. A rolled IPE is not a pair of rectangles plus a web sketched on the back of an envelope.
W ≥ M / σallow
That check is stress only. Deflection, lateral-torsional buckling and shear are separate checks.
Asymmetric sections (T, L, U): two section moduli
A rectangle, a round bar, a doubly-symmetric I: the neutral axis is a symmetry axis. The distance v is the same top and bottom, and a single W covers both fibres.
A T, an angle, a channel, a slab with a downstand: the centroid is not at mid-depth. The top fibre sits at vtop, the bottom at vbot, and the two distances are not equal. Same I, two moduli. Stress is higher on the side with the smaller W, because that fibre is farther from the axis. On a T, that side is almost always the stem tip — the flange sits close to the centroid, the stem sticks out.
Where the material is weaker in tension than in compression (cast iron, unreinforced concrete), the thick side is placed on the tension face. The large v falls in the stronger material, on the compression side. A reinforced-concrete T-beam is arranged the other way. Under sagging, the slab flange is in compression and the steel sits in the stem.
Wtop = I / vtop · Wbot = I / vbot
The form treats the three symmetric shapes. For a T, I is required about the centroidal axis: centroid, second moment, and the two values of v.
Standard steel profiles: reading W from a catalogue
A rolled I-beam rebuilt from rectangles loses the fillets. EN 10365 (IPE, HEA, HEB, HEM) and the hollow-section tables already list the properties used in design.
- depth, width, flange and web thickness
- mass per metre (kg/m) and area A (cm²)
- second moments Iy, Iz (cm⁴)
- elastic moduli Wel,y, Wel,z (cm³)
- radius of gyration* i = √(I/A) (cm) — a section property, not a mass property
- plastic moduli Wpl,y, Wpl,z on most modern tables
An IPE 200, a section commonly held in stock, has Wel,y ≈ 194 cm³ about the strong axis. That is the number set against M / σ. Preliminary sizing stops there. Final design checks deflection, shear in the web, and lateral-torsional buckling if the compression flange is unrestrained. Cold-formed sections and welded plate girders are not in those hot-rolled tables. For those, W is computed, or taken from the manufacturer’s sheet.
Elastic versus plastic section modulus
W on this page is the elastic modulus: linear stress, σ = M y / I, with the extreme fibre just at yield. The symbol is Wel when that value has to be distinguished from Wpl.
Once a ductile steel section can form a plastic hinge, the stress block is no longer a triangle. It is two rectangles at fy, tension on one side of the plastic neutral axis, compression on the other. The moment of that fully plastic state is Mpl = fy Wpl. The plastic section modulus* Wpl is the first moment of area about that axis, and it has nothing to do with I. The ratio Wpl / Wel is the shape factor*: 1.5 for a solid rectangle, about 1.12 to 1.20 for a compact I, 2.0 for a diamond, about 1.7 for a solid round.
Eurocode 3 permits Wpl on Class 1 sections and, for cross-section capacity, on Class 2. Class 3 stays elastic. Class 4 is slender enough that the plate buckles before yield, and the check uses an effective W. AISC draws the same distinction with different letters: S is elastic, Z is plastic, and a compact W-shape is designed on Z in LRFD.
Mpl = fy · Wpl · shape factor = Wpl / Wel
Timber, cast iron, concrete in tension: no plastic modulus. The check stays on Wel.
Optimising a section at equal mass: why a tube beats a solid disc
Material on the neutral axis is dead weight in bending.
It adds area, mass and cost, and almost nothing to I or W: y is small. The same steel, moved out to the skin, raises both numbers.
Solid round bar, diameter 40 mm: A = 1,257 mm², W = π R³ / 4 ≈ 6,283 mm³. Tube of the same area, 50 mm outside: inner radius 15 mm, W = π (Rext⁴ − Rint⁴) / (4 Rext) ≈ 10,680 mm³ — about 70 % more modulus for the same kilograms per metre. A thinner wall than that keeps raising W, until local wall buckling or handling damage sets the limit. Bicycle frames, aircraft spars, drive shafts that can be hollow, and boom chords are tubes rather than bars. An I-beam is the same idea with the sides cut off: two flanges far from the axis, a skinny web to keep them apart and to take the shear.
Wtube = π (Rext⁴ − Rint⁴) / (4 · Rext) = π (D⁴ − d⁴) / (32 D)
A thin tube is a poor choice where torsion has to be carried without ovalising, or where a forklift tine can dent the wall. Equal-mass is not equal-duty.
Where this page stops, where beam bending starts
The calculation stops at W. Span, load and support conditions are not inputs.
The companion beam bending page takes a simply supported span or a cantilever, a point load or a uniform load, and returns the peak moment M, the reactions, the deflection, and σ = M/W once a section is known. Typical closed forms: M = F L / 4 at mid-span for a central point load, M = q L² / 8 for a uniform load on two supports, M = F L at the root of a cantilever. W comes from this page; M comes from that one; the stress is the ratio. Shear force, E I deflection, and the shape of the moment diagram live on that page, not on this one.
A complete check uses both. W without M is a catalogue number. M without W is a load case.
Worked examples: a floor beam and a drive shaft
Two jobs that look different and use the same division.
Timber floor joist
Solid timber, C24, with a working bending stress of 10 MPa (a round allowable after kmod and γM; the characteristic fm,k is 24 MPa). Span 4.0 m, simply supported, uniform load 5.0 kN/m including self-weight.
M = q L² / 8 = 5,000 × 16 / 8 = 10,000 N·m
W ≥ 10,000 / 10×106 = 1.0×10−3 m³ = 1,000 cm³
Rectangle, W = b h² / 6. With b fixed at 75 mm:
75 × h² / 6 ≥ 1,000,000 mm³ ⇒ h ≥ √(80,000) ≈ 283 mm
A stock 75 × 300 mm joist gives W = 75 × 300² / 6 = 1,125,000 mm³ = 1,125 cm³, which clears the stress check. Deflection is another matter: f = 5 q L⁴ / (384 E I) often governs in floors long before 10 MPa does. That check is run on the bending page with I = b h³ / 12 of the section just sized.
Drive shaft in bending plus torsion
Steel shaft, 40 mm diameter, allowable 200 MPa. Torque 300 N·m. A pulley applies a bending moment of 150 N·m. The bending modulus of a solid round is π d³ / 32, the same number as π R³ / 4 on this page. The torsional modulus of a round is twice that, π d³ / 16.
W = π × 40³ / 32 ≈ 6,283 mm³ · σ = 150,000 N·mm / 6,283 ≈ 23.9 MPa
Wt = π × 40³ / 16 ≈ 12,566 mm³ · τ = 300,000 / 12,566 ≈ 23.9 MPa
σeq = √(σ² + 3 τ²) = √(4 × 23.9²) = 47.8 MPa (von Mises)
47.8 MPa against 200 MPa: the shaft is idle on strength. Fatigue at the keyway, or twist along a long line, may govern the size. Combined stress is not a W problem alone; it is W, Wt and a yield criterion.
AISC S versus Eurocode W
Same quantity, two alphabets.
Europe writes W (Wel, Wpl) in cm³ on the steel tables. The United States writes S for the elastic modulus and Z for the plastic modulus, in in³, in the AISC shapes database. Sx is strong-axis elastic, Sy weak-axis; Zx and Zy likewise. The W from this calculator is S, in SI.
1 in³ = 16.387 cm³. That conversion is the usual trap.
A W12×50 has Sx ≈ 64.7 in³ ≈ 1,060 cm³, a different animal from an IPE 200 at 194 cm³. A moment in kip·ft with S in in³ needs the 12: σ(ksi) = M(kip·ft) × 12 / S(in³). SI is quieter: M in N·mm and W in mm³, or kN·cm and cm³, and σ lands in N/mm² = MPa. ASD in AISC compares M/S with Fb; LRFD compares Mu with φb Fy Z for a compact section. The geometry did not change. The safety format did.
SAISC ≡ Wel, Eurocode · ZAISC ≡ Wpl, Eurocode
A drawing stamped in Chicago that quotes Sx = 20.8 in³, read in a mill working in millimetres, needs the conversion before a European IPE is chosen to match it.
Strong axis and weak axis
A joist is almost always bent about its strong axis: the deep direction. That same 75 × 300 mm timber, laid on its side, drops W from b h² / 6 to h b² / 6, here from 1,125 cm³ to 281 cm³ — a quarter, because the depth in the formula is the dimension in the plane of bending. I-beams make the gap even louder: an IPE 200 has Wel,y ≈ 194 cm³ and Wel,z ≈ 28 cm³. Wind on a column, or a beam used as a lintel with the web horizontal, is a weak-axis problem.
The rectangle on this page takes b as width and h as the dimension in the bending plane, the one that goes with v = h/2. The two are swapped in the form when the load lies in the other plane. A circle is isotropic, and a round section has no weak axis. A tube is isotropic in bending until the wall ovalises.
Both axes need a check when the moment has two components — a shaft with pulleys in two planes, a crane rail with vertical load and surge. A section generous on the strong axis can be inadequate on the weak one.
When W is not enough
Clearing σ = M/W does not close the job.
- Deflection. Floors, machine beds, crane girders: L/300, L/400, a millimetre of camber. That is an I problem (and an E problem), not a W problem. A short deep beam can pass on stress and fail on sag.
- Lateral-torsional buckling. A slender I, compression flange free, unrestrained length a few metres: the beam rolls over before the extreme fibre yields. Eurocode and AISC both reduce the moment capacity. Wel is only the starting point.
- Shear. Short, heavily loaded members. Average τ = V / Aweb, or 1.5 V/A on a rectangle. A deep thin web can yield in shear while the bending stress remains modest.
- Holes, notches, welds. A hole in a flange removes area where y is largest, and W falls faster than A does. A keyway in a shaft is a stress raiser on top of the W calculation; fatigue lives there.
W from this page is the elastic modulus of a plain rectangle, a solid round or a round tube, about a centroidal axis. It is not a buckling check, not a fatigue factor, and not a plastic modulus. It is not a basis for loading the part to σallow and stopping there.
A burned hole in a flange, cut after the beam is up, is a new section. W is recalculated on the net area, or the hole is not cut.
I, W, and mass moment: three different numbers
The family of pages around this one shares letters and not much else.
- Second moment of area I — m⁴, geometry of the cross-section. Stiffness in bending. This page computes it on the way to W.
- Section modulus W (or S) — m³, cross-section geometry. Stress in bending. That result is what this page returns.
- Mass moment of inertia — kg·m², how the mass is spread about a spin axis. Dynamics, flywheels, motor sizing. The mass moment calculator is that quantity. CAD reports labelled “Ixx” are sometimes this, sometimes the area property; the unit decides.
The centre of gravity of a set of masses is another object: a point, not a stiffness. It is required before a mass moment is shifted with the parallel-axis theorem, and it shows which way a trailer or a machine will sit. For a shaft under bending and torsion, the torsion page uses a polar modulus, not this W. For a solid round the polar modulus is exactly 2W, the identity behind the matching stresses in the shaft example.
Glossary
- Elastic section modulus
- W = I / v, a length cubed. It turns a bending moment into extreme-fibre stress while that stress varies linearly over the depth: σmax = M / W.
- Second moment of area
- I, a length to the fourth. It measures how the area is spread about an axis and sets the bending stiffness E I. It is not a mass moment of inertia.
- Extreme fibre
- The point of the cross-section farthest from the neutral axis, at distance v. In elastic bending it is where the normal stress reaches its peak.
- Bending stress
- Normal stress produced by a bending moment. At a distance y from the neutral axis, σ = M y / I. On the extreme fibre that is σmax = M / W.
- Plastic section modulus
- Wpl, the first moment of area about the plastic neutral axis. For a ductile section at full plastification, Mpl = fy Wpl. It does not come from dividing I by v.
- Shape factor
- The ratio Wpl / Wel. It depends on the shape of the cross-section, not on the material.
- Radius of gyration
- i = √(I / A), a length. A section property used for buckling slenderness, not a property of the mass.