French DPE Calculator: Estimate a Home's Energy Rating
The DPE (diagnostic de performance énergétique) is France's home energy performance certificate. It rates a home from A to G on two separate criteria: its primary energy consumption (kWh/m²/year) and its greenhouse gas emissions (kg CO2/m²/year). Since the 1 July 2021 reform, the rating shown is the worse of the two — which is why an all-electric home, with very low CO2 emissions, can still cap out at class B: electricity is counted at 1.9 times its actual consumption in primary-energy terms (2.3 times between 1 July 2021 and 1 January 2026, when a further regulatory adjustment took effect).
This tool estimates a rating from a home’s main characteristics — floor area, insulation, heating, hot water, ventilation — following the same overall logic as the official method (heat loss, heating need, conversion to primary energy, worst-of-two rule).
This is an estimate, not a substitute for the assessment carried out by a certified assessor (diagnostiqueur), the only person authorised to issue a legally valid DPE (required in France to sell or let a property). It is here to anticipate a result or sanity-check one already received — see the note under the results.
Home characteristics
French energy-label jargon marked with an asterisk is spelled out in the glossary under the article.
The official 3CL-DPE method versus this estimate
This page estimates a French DPE* (diagnostic de performance énergétique). It is not a UK Energy Performance Certificate, not an Irish BER, not a US Energy Star score. France rates homes with its own engine, 3CL-DPE*, run by a certified assessor (diagnostiqueur) after a site visit. The software walks the fabric wall by wall: U-values, thermal bridges, windows, ventilation, the heating generator, domestic hot water, auxiliaries, solar and internal gains, month by month.
What is typed here is a sketch of that physics. A shape factor for the envelope, a typical U-value for the build period, degree-days for a broad climate zone, a 2.5 m ceiling. No blower-door test. No measured lintel. No month-by-month solar file.
- Official 3CL-DPE — on-site survey, every surface entered, legal document for a French sale or let.
- This estimate — declared inputs, average coefficients, a letter that can rank options against each other.
- The bills — how the household actually lives. The DPE is conventional occupancy, not last winter’s thermostat.
A real assessor can land one letter away from this page, sometimes two. Use it to ask “loft first or heat pump first?”, not to print a class on an advert. There is no English 3CL engine on this site; the calculation is the French method, sketched.
Energy class, climate class, and the worse-of-two rule
Since the 1 July 2021 reform, the certificate carries two scales. One is primary energy* in kWhEP/m²/year. The other is greenhouse gas in kg CO2/m²/year. The letter on the front is the worse of the two.
class shown = worse of (energy class, climate class)
A leaky house on a modern heat pump can look decent on CO2 and ugly on kWh. A tight house on an old oil boiler can do the reverse. The dual threshold exists so a dirty fuel cannot hide behind a tidy kilowatt-hour figure — and so a clean grid cannot excuse a sieve.
- Energy thresholds (kWhEP/m²·yr): A ≤ 70, B ≤ 110, C ≤ 180, D ≤ 250, E ≤ 330, F ≤ 420, else G.
- Climate thresholds (kg CO2/m²·yr): A ≤ 6, B ≤ 11, C ≤ 30, D ≤ 50, E ≤ 70, F ≤ 100, else G.
- Energy B and climate D → the sticker is D. Energy C and climate A → the sticker is C.
Classes F and G: rent freezes and letting bans
French law calls F and G homes passoires thermiques* — thermal sieves. They are not just a bad label. They are a letting problem with a published timetable.
- 24 August 2022 — rent freeze on F and G: no index-linked uplift, no increase at renewal.
- 1 January 2023 — the worst G stock (final energy above 450 kWh/m²·yr) already fails the “decent housing” test.
- 1 January 2025 — new lets of class G banned.
- 1 January 2028 — class F follows. 1 January 2034 — class E.
Existing tenancies run to their term. The crunch is re-letting and renewing. A landlord who ignores the dates is not being clever with rental yield — the income is not there if the flat cannot be offered. Fines exist; so does an order to do the works.
This timetable is French statute, not a UK MEES rule and not a local by-law. If a French property is let, the letter on the DPE is the one that counts — an English EPC on a London flat tells nothing about a house in the Dordogne.
How the letter moves a sale or a let
French buyers now filter by letter. Notaires and agents report discounts on F and G on the order of 10% to 20% against a similar C or D, more where the bank will not count the rent until the works are done. Time on market stretches. Viewings thin out once the advert shows a red G.
A and B can carry a small green premium. The larger effect is finance. Some lenders haircut the rental they will accept on a sieve, which hits both the price that can be bid and the monthly payment that can be serviced. A cheap G with a costed works plan can still be the right buy — the renovation is being priced, not wished away.
For a landlord, the letter is occupancy risk as much as price. A frozen rent on an F, then a ban on re-letting, is a vacancy that cannot be advertised out of.
MaPrimeRénov’, CEE and éco-PTZ
France pays people to move the letter. The stack is the point, and the euro amounts move with each budget — treat last year’s flyer as stale.
- MaPrimeRénov’ — Anah grant, income-banded, paid against a package of works and the number of classes gained.
- CEE (energy-saving certificates) — a supplier obligation: EDF, Engie and the rest fund insulation and heating swaps. Stacks with MaPrimeRénov’.
- éco-PTZ — interest-free works loan, no income test, capped (commonly up to €50,000 depending on the package).
- 5.5% VAT — energy-performance works by an RGE* contractor (Reconnu garant de l'environnement).
The constant: a qualified pro, an invoice that matches the scheme rules, and a fresh DPE after the works to prove the jump. DIY loft rolls from the shed do not unlock the grant.
Why all-electric dwellings often stop at B
Electricity is multiplied in primary-energy terms. The coefficient is 1.9 from 1 January 2026 (it was 2.3 from the 2021 reform until that date). The A–G thresholds did not move.
kWhEP = kWhfinal × 1.9 (electricity)
Resistance heaters: almost every delivered kilowatt-hour hits the energy scale. A 50 kWh/m² final bill becomes 95 kWhEP — class B (A needs ≤ 70). Class A on panel heaters means roughly 37 kWh/m² of electricity. That is passive-house territory.
A heat pump changes the arithmetic. A seasonal COP of 3 turns 50 kWh of heat into about 17 kWh of electricity, about 32 kWhEP. Class A is then in play if the envelope is decent. A leaky house with a heat pump still runs the compressor all winter — envelope first, generator second. “All-electric” is not one category: a 1980s grille and a 2024 air-to-water unit do not live on the same label.
Validity of a DPE and blank certificates
A DPE issued from 1 July 2021 is valid 10 years. Older vintages were retired on a timetable: certificates from 2013–2017 died at the end of 2022; those from January 2018 to 30 June 2021 died at the end of 2024. A sale or a let cannot ride on a dead letter.
A DPE vierge — a “blank” DPE — was a certificate issued without enough data to compute a class. It showed up on some off-plan (VEFA) and very new homes. It is not a dodge for an existing flat that is to be let. Since 2021 the sale-or-let DPE has to come from a real visit. If a listing waves a blank sheet, ask why the assessor never went inside.
Which works move the letter first
The letter moves when losses drop or when the fuel and the efficiency of the generator change. Not every euro of works buys the same jump.
- Loft / attic — on a house, the roof is often 25% to 30% of the loss. 30 cm of mineral wool is the cheap class-gainer. Do this before sizing a heat pump.
- Walls — external insulation treats thermal bridges and keeps the floor area. Internal insulation is cheaper and eats rooms. Either can be a one- or two-class move on a sieve.
- Oil or old gas → heat pump — the climate label jumps; the energy label jumps if the COP is real and the emitters are warm enough. Oversized on a sieve, it just cycles.
- MVHR (balanced ventilation with heat recovery) — pays once the envelope is already tight. On a draughty 1970s box, fix the box first.
Windows last. They look expensive on a quote and they rarely move the DPE as far as the loft. Nice to have, not the first invoice.
DPE versus the regulatory energy audit
Two documents, two jobs. Mixing them up is how a buyer thinks a €200 sticker is a works programme.
- DPE — mandatory to sell or let. A–G, conventional consumption, stock recommendations. Half a day, a few hundred euros.
- Regulatory energy audit (audit énergétique) — mandatory on the sale of F/G individual houses and buildings in single ownership since 1 April 2023 (class E from 2025). Scenarios, costs, savings, a day on site, closer to four figures.
The DPE is the label. The audit is the roadmap. An apartment in a copropriété follows different rules — the audit duty is not a blanket on every F-rated studio in a tower. If a French house in F or G is being bought, budget for the audit in the data-room, not as an optional extra.
French DPE, UK EPC and Irish BER: three labels, three jobs
The A–G rainbow looks familiar. The numbers behind it do not travel.
A UK EPC* (England and Wales) is a SAP / RdSAP model. It talks running cost and a separate environmental-impact rating. To let, MEES* (Minimum Energy Efficiency Standards) currently wants a minimum E, with a tighter band promised for later. Scotland and Northern Ireland run their own variants. None of that is 3CL, none of it uses the French worse-of-two rule, and a London EPC of C says nothing about a Breton farmhouse.
An Irish BER (Building Energy Rating) is another A–G scale, built on IS 439 / DEAP. Again: not 3CL, not a French letting ban. Energy Star in the United States is a voluntary EPA label for new homes and for appliances. It is not a mandatory certificate at sale. US listing sheets may show a HERS index or a local score. If a US listing agent calls a French DPE “the French Energy Star”, the mental model is wrong — this document can freeze a rent and ban a let.
When two homes are compared, compare two French DPEs, or two UK EPCs, never a mix. The letters share a typeface, not a method.
Buying a French home from abroad
The PDF in the notaire’s pack is a legal paper, not a brochure. Check the date (is it still in force?), the floor area used, the heating fuel, and whether the class is pulled down by energy or by climate. A climate-D / energy-B house is a fuel problem. An energy-F / climate-C house is a fabric problem. The works are not the same.
Ask who paid the assessor. A vendor-commissioned DPE is still official — it is also the vendor’s document. If the letter decides the bid, a second visit is cheaper than a bad purchase. Read the recommendations as a shopping list, not as a quote: 3CL suggestions are generic. A local RGE contractor prices the actual roof.
A real-estate bid that ignores the letter is a bid that ignores French statute. Lenders who will fund a borrowing capacity on a C may haircut an F until the works are done.
The floor area the DPE uses is not the one in the listing
French adverts mix surface Carrez (lot floor area in a copropriété), surface habitable (SHAB), and the odd “useful” figure the agent likes. The DPE divides consumption by the area the assessor entered, which should be the heated habitable area under the 3CL rules — not the garden, not the unheated garage, not always the Carrez number on the compromis.
A 10% smaller denominator lifts kWh/m² by 10% and can tip a D into an E. If this calculator and the official certificate disagree, check the m² first, then the insulation story. Do not “optimise” the area on this form to hunt a letter. The assessor will measure.
Thermal bridges at floor edges, a north-facing glass wall, a boiler that is 18 years old but still “condensing” on the nameplate, intermittent heating in a weekend house, a wood stove that is the only heat, occupancy of one person in 140 m²: none of that is in the drop-downs. The official method is conventional: set indoor temperatures, set occupancy, set hot-water litres per person. The real bill can be half of that, or double. The DPE exists so two flats can be compared on the same conventional life — not so last winter’s EDF statement becomes the class.
This result has no legal value in France. Only a certified assessor can issue the DPE required to sell or let. Treat a letter from this page as a ranking tool, then book the visit.
Glossary
- DPE
- Diagnostic de performance énergétique: France’s mandatory energy-performance certificate for sale or let. Two scales (primary energy and CO2), A to G, the worse of the two shown. Not a UK EPC and not an Irish BER.
- 3CL-DPE
- The official French calculation engine used by certified assessors. Wall-by-wall fabric, month-by-month gains, conventional occupancy. This page is a sketch of that method, not a substitute for it, and there is no English 3CL engine on the site.
- kWhEP
- Kilowatt-hours of primary energy. Final consumption is multiplied by a coefficient per fuel (electricity 1.9 from 1 January 2026; fossil fuels near 1). The energy class is kWhEP per square metre per year.
- Passoire thermique
- “Thermal sieve”: informal name for a class F or G dwelling. French statute freezes the rent and then bans new lets on a published timetable (G from 2025, F from 2028, E from 2034).
- RGE
- Reconnu garant de l'environnement: a contractor qualification required for many French energy-works grants and for the 5.5% VAT rate. DIY does not unlock MaPrimeRénov’.
- EPC / BER
- UK Energy Performance Certificate (SAP/RdSAP) and Irish Building Energy Rating. Both use an A–G rainbow. Neither is 3CL, neither carries the French F/G letting bans, and neither can be compared letter-for-letter with a DPE.
- MEES
- Minimum Energy Efficiency Standards: the English and Welsh letting-rating floor (currently E on the EPC scale). A separate regime from the French F/G letting bans, on a different certificate.