Bearing static safety factor (s₀ = C₀/P₀)
Fatigue life concerns a bearing that turns. But a bearing can also be damaged at rest: under a high load, a stationary ball or roller can dent its raceway with a permanent mark (indentation, or "brinelling"). The static safety factor s₀ = C₀/P₀ checks that this does not happen.
It is the “at rest” counterpart of rating life: the comparison is no longer a duration but a load — the static capacity C₀ of the bearing against the actual static load P₀. Shocks, vibration and peak loads are checked here, not in the life calculation.
Static loads
Static-rating jargon is glossed once, via the asterisk, in the glossary.
Indentation at rest: what actually happens
A turning bearing shares the load around the race. A parked one does not. Two or three rolling elements take almost everything, the Hertzian patch sits still, and once the stress climbs past the elastic limit the steel yields. What is left is a permanent mark — a Brinell dent in the raceway, sometimes a matching flat on the ball or roller. Standards and catalogues call that mark plastic indentation*. Millwrights call it brinelling, when the language stays polite.
Once the shaft turns again, the bearing runs noisy and rough once per revolution, every time a rolling element climbs in and out of that dent.
The life formula is not interested. This is not spalling from millions of cycles; it is a stamp from one overload. A luxurious L10h can sit beside a ruined raceway after a single press stroke with the rotor locked.
The check against that stamp is the static safety factor s0*: the basic static load rating C0* divided by the equivalent static load P0*.
s0 = C0 / P0
C0 is the load the bearing takes without a useful dent. P0 is the load applied while the bearing is still, or barely creeping. The ratio is the whole definition. The remaining choice is the minimum s0: noise, shock, and whether a dent puts people at risk.
What ISO 76 means by C0
The basic static load rating is a convention, not a “first yield” in the tensile-test sense. ISO 76* defines C0 as the load that produces a total permanent deformation — rolling element plus raceway — of 0.0001 times the rolling-element diameter at the most heavily loaded contact. A 10 mm ball: 1 µm of set. That set is taken to have no practical consequence on later running: inaudible, and too small for a shop indicator to show as a step.
Above C0 the dent grows. How far it may grow depends on the machine, which is why s0 is a chosen margin and not a law of nature.
Precision spindles treat 0.0001·D as already too much. A slow conveyor idler will live with less. The catalogue figure does not change between those two machines; the factor does.
Which of C and C0 is larger depends on the type. A 6208 deep-groove might show C ≈ 32 kN and C0 ≈ 19 kN — dynamic rating on top. A big spherical roller often reverses that, with C0 the heavier figure. The two numbers answer different questions, and there is no reliable “C0 is 70 % of C” rule for the day the PDF fails to load.
P0 = X0·Fr + Y0·Fa
Static factors come from the same catalogue. On a deep-groove ball bearing they are typically X0 = 0.6 and Y0 = 0.5.
P0 is an equivalent static load, not a raw radial force. If the sum comes out smaller than Fr, the static load is taken as P0 = Fr: a radial bearing is never credited with a static load below the radial component. Peak shock at rest, the crane hoist just seated, the cold-start torque of a mill — those peaks are P0, even when they last a second.
Choosing a minimum s0
The form defaults are C0 = 20 kN and P0 = 8 kN, which gives s0 = 2.5. That is already a comfortable shock-and-quietness figure, not a bare pass. ISO and the manufacturers publish bands, not a single sacred number. The bands below are the usual workshop reading of those publications.
- s0 ≈ 0.5 to 1 — lightly loaded bearing, turning slowly, with no quietness requirement. A dent at 0.0001·D is academically there and nobody will hear it. Not a spindle. Not a lift.
- s0 ≈ 1 to 1.5 — normal operation, smooth running. Most industrial gearboxes and ordinary motors sit in this band when the load is steady.
- s0 ≈ 1.5 to 2.5 — quiet running required, or moderate shocks and vibration. Fans in an occupied room, a pump next to an office, a machine that sees the odd knock.
- s0 ≥ 2.5 to 4 — heavy shocks, high running accuracy, safety of people. Presses, cranes, wheel bearings, anything that can drop a load on someone.
Roller bearings, line contact, often sit at the higher end of each band for the same duty: the dent is a line, not a point. Quietness is less of a ball-bearing problem, but shock leaves a mark. Ball bearings in a silent instrument take the high s0 even when the load looks modest, because the noise spec is the spec.
s0 < 1 is not automatically a cracked ring. It is a dent that has been accepted — and that acceptance belongs in the report.
Static check versus rating life
Two independent checks. Both of them. The one left out is the one that fails.
- Rating life L10* — basic dynamic load rating C*, equivalent dynamic load P, speed n. How long the turning bearing resists fatigue. ISO 281, on the rating life page.
- Static safety s0 — basic static load rating C0, equivalent static load P0. The maximum load the bearing withstands at rest without marking the raceway. ISO 76, this page. P0 is not P; X0 and Y0 are not X and Y. P0 is built the way the equivalent load page builds P, with the static table.
A slow but heavily loaded bearing is often sized by statics: a slewing ring, a swing bridge, a screw jack, a kiln that turns at 0.5 rpm. L10h looks infinite because n is tiny; the raceway can take a set all the same. A fast bearing under a moderate load is sized by fatigue: C/P and hours. A machine that sees rare peak overloads — at rest, or on start-up — needs s0 on those peaks when the rating life is otherwise more than sufficient.
Oscillating bearings — a robot wrist, a dump-truck pivot — sit in the middle. The ring does not complete revolutions, so L10 in millions of revolutions is an odd unit, and the load often dwells. Static safety plus a wear argument usually beat a naive L10h.
None of that excuses skipping C0.
C0 is not C
Two columns, two symbols, two ISO standards. C is the basic dynamic load rating (ISO 281). C0 is the basic static load rating (ISO 76). They are measured, and defined, differently. Using one for the other completely falsifies the result: s0 computed with C is not s0, and L10 computed with C0 is not L10.
C does not belong in this form, and C0 does not belong in the life form. A blurred catalogue line is magnified, not guessed.
6205-2RS1, a size found in almost every drawer: C and C0 are a few kilonewtons apart, and the wrong one looks “about right” at 1 a.m. Close enough? It is not. The same split applies to P and P0. A deep-groove under Fr = 4 kN and Fa = 2 kN might have P ≈ 5.2 kN with X = 0.56 and Y = 1.5, and P0 = max(Fr, 0.6×4 + 0.5×2) = max(4, 3.4) = 4 kN. Different number. Different check. Reusing P “to save a line” spends the wrong line.
False brinelling: vibration while parked
True brinelling is plastic indentation from a load that was simply too big.
False brinelling* is something else: fretting wear at the rolling-element pitch, from small oscillations or vibration while the bearing is not turning enough to rebuild an oil film. The marks sit at ball spacing, look like a chain of bruises, and are often mistaken for overload dents. They are not. s0 was fine. The film was gone.
Classic victims stay parked while something else shakes: electric motors stored on a vibrating floor, spare fans that ride a lorry across a continent, generators on standby next to a running set.
Grease is pushed out of the Hertzian patch, metal meets metal, and oxide debris starts a red or black stain. The first day of service sounds like gravel.
- Stored machines are turned now and then, and the elements rest on a fresh patch of grease.
- The shaft is locked for transport when the handbook requires it — or the skid is isolated from the trailer bed.
- Standby equipment: a slow, periodic jog is cheaper than a set of spindle bearings.
The pitch of the marks separates the two. Overload from a radial load leaves dents in the loaded zone, often on one side. False brinelling rings the race at every element, all around: vibration does not pick a loaded arc the way a static force does. s0 is the check for a true overload. Storage is a grease-film problem. False brinelling is not cured by a bearing with a bigger C0.
Shaft and housing fits, and the load that is not in the catalogue
C0 assumes the rings are seated the way the manufacturer drew them. An inner ring that creeps on a loose shaft seat frets, heats, and then loses interference until the whole assembly is a rattle. That extra dynamic load never entered P0.
The usual culprit is the rotating ring. An inner ring rotating relative to the load calls for interference on the shaft — k5, k6, m6, n6 as the load gets heavier. A stationary inner ring, a wheel on a stub axle, can be a slide fit; the housing then takes the interference.
The other ring usually has to float axially, so that thermal growth of the shaft does not pump a static preload into both bearings. Locating bearing: inner and outer axially fixed. Non-locating bearing: one ring free to slide. Two locating bearings on a long steel shaft in a cast housing is a textbook way to build an unintended P0 as soon as the motor warms up. The catalogue did not include that load. The fit table did.
- Shaft, rotating inner ring, moderate load — k5 or k6 is the everyday motor and gearbox choice.
- Heavy load, shock, large size — m6, n6, sometimes p6; the clearance taken by the fit is often put back with C3.
- Housing, floating outer ring — H7, a proper sliding fit, round, not a file-fitted oval.
- Adapter sleeve on a drawn shaft — spherical roller plummer blocks are built on this; an overtight nut invents preload and a standing P0.
A thin-walled housing that bellies under bolt load pinches the outer ring into an oval. Diametral clearance disappears on two lobes, preload appears on the other two, and s0 computed on the drawing load is a fiction. Roundness is checked after bolting, not before. A split plummer block with a lid torqued down onto a proud outer ring will do the same trick.
Mounting mistakes that look like a static failure
A surprising fraction of “the bearing was undersized” reports are mounting. The raceway is marked, s0 on paper was 3, and the dent was put in with a hammer.
- Blows through the rolling elements — driving the inner ring on by hitting the outer, or the other way round. Every ball is then a punch. A tube against the ring being seated, a press, or an induction heater does the job (inner ring, 80 to 110 °C, never a flame on the race).
- A locknut used as a press — winding a shaft nut until the bearing is hard against a shoulder meant as a stop. That applies an axial P0 equal to the nut preload, which never entered this form.
- Cold inner ring on a heavy interference — it picks up, galls, and sits a few tenths out of square. Misalignment on a deep-groove is a few minutes of arc; beyond that the loaded zone is a nightmare and the standing contact is a knife-edge.
- Dirt on the seat — a chip under the inner ring is a local dent before the machine has turned. It photographs like brinelling. It is a clean-the-seat problem.
Angular-contact pairs have their own talent for this. Stacked the wrong way, or with the sprung preload forgotten, one row unloads and the other takes the whole Fa. An s0 based on “half the load each” was a daydream. The ring is heated, seated home, and the rotation felt; residual clearance is measured when the drawing asks for it. On a 100 mm taper bore the heater is part of the job, not a flourish.
Temperature, C3 clearance, and a standing load
Internal clearance is not a luxury suffix. Normal (CN) is the default; C3 is greater than normal, and C4 greater again.
C3 comes in when an interference fit will eat some of the clearance, when the inner ring will run hotter than the outer (motors, high speed), or when both happen at once. A CN bearing mounted on a k6 shaft in a warm stator can run at zero or negative clearance. That is a standing preload, a standing P0, heat, and a short grease life, next to a fatigue calculation that looks pretty.
Temperature drops C0 a little — the steel is softer — but the everyday damage comes from the clearance and the lubricant, not from a 5 % derating of C0 at 120 °C.
Above about 120 to 150 °C a stabilised heat treatment is required (SKF suffix S0, S1, S2), or the ring dimensions wander and the clearance that was paid for is gone. Below that range, C3 is chosen when the fit and the gradient call for it, not from a sense that C3 “sounds heavy-duty”.
A standing axial load on a hot machine — thermal growth against two locating shoulders — is the quiet way to fail a static check that was never run. One bearing locates. The other floats. The float has to keep sliding after six months of fretting, which is why that H7 seat is machined, not painted. Two locked 6309s on a 400 mm span do not keep the assembly value of s0 once the shaft is at 80 °C. The growth is computed, or the drawing is changed.
Glossary
- Basic static load rating C₀
- The ISO 76 load that leaves a total permanent set — rolling element plus raceway — of 0.0001 times the rolling-element diameter at the heaviest contact. It is the numerator of s₀, not the dynamic rating C.
- Equivalent static load P₀
- One static load for radial and axial force together, X₀·Fr + Y₀·Fa, never taken below Fr on a radial bearing. A shock peak at rest counts, including a peak of one second.
- Static safety factor s₀
- The ratio s₀ = C₀ / P₀: how far the equivalent static load sits below the basic static load rating. The minimum follows the duty — quiet running, shock, accuracy, or safety of people.
- Plastic indentation
- A permanent dent where a stationary ball or roller has pushed the raceway past the elastic limit. Catalogues say indentation; the shop often says brinelling. One overload, not fatigue spalling.
- False brinelling
- Fretting at rolling-element pitch, from vibration while the bearing does not turn enough to keep an oil film. The marks look like overload dents. s₀ does not describe them, and a larger C₀ does not remove them.
- Basic dynamic load rating C
- The ISO 281 load for fatigue life of a turning bearing. A different column from C₀. An s₀ worked out with C is not s₀.
- Rating life L₁₀
- Fatigue life of a turning bearing, from C, P and speed, in millions of revolutions or in hours as L10h. A dent made at rest stays outside that account.
- ISO 76
- The standard that defines the basic static load rating and the permanent-deformation criterion behind C₀. This page follows it. Fatigue life follows ISO 281.