Heat travels in three ways: by conduction (step by step through matter), by convection (carried by a moving fluid) and by radiation (electromagnetic waves, needing no medium). Pick the mechanism — or combine conduction and convection for a real wall — and read off the heat flow and the related quantities.

The heat flow Q̇ is measured in watts (W): it is a power. The heat flux φ = Q̇/A is in W/m². A high thermal resistance slows the transfer down.

Mechanism and inputs

Mode of transfer

Switch mechanism, then run the calculation again to update the fields.

Wall (conduction + convection)

A difference is the same in °C and in K.

Result

  • U-value 0.375 W/(m²·K)
Inner surface resistance 1/hᵢ 0.1299 m²·K/W
Conduction resistance e/λ 2.5000 m²·K/W
Outer surface resistance 1/hₑ 0.0400 m²·K/W
Total surface resistance 2.6699 m²·K/W
Thermal transmittance U 0.375 W/(m²·K)
Heat flow Q̇ (A = 10.00 m², ΔT = 20.00 K) 74.91 W
Heat flux φ 7.49 W/m²
Total thermal resistance R 0.2670 K/W
Inner surface (1/hᵢ)94 %Material (e/λ)Outer surface (1/hₑ)
Breakdown of the wall's thermal resistance: the widest segment is the main brake on the transfer (usually the insulation).

Q̇ = A · ΔT / (1/hᵢ + e/λ + 1/hₑ) · U = 1 / R

The three modes of transfer

Heat does not pick a favourite. It takes whichever path is open. Three mechanisms, three formulas, often running at the same time:

  1. Conduction — through a solid, no bulk motion. Fourier: Q̇ = λ·A·ΔT / e. Low conductivity λ or a large thickness e cuts the flow. Copper is a motorway (λ ≈ 390 W/(m·K)). Glass wool is a dirt track (λ ≈ 0.040).
  2. Convection — a fluid carries the heat off a surface. Newton's law of cooling: Q̇ = h·A·ΔT. The film coefficient h is not a material property; it is a flow property. Still air is about 10 W/(m²·K). Forced air, 50. Water, hundreds to thousands. Condensing steam, around 10,000.
  3. Radiation — electromagnetic, no medium required. Stefan–Boltzmann: Q̇ = ε·σ·A·(T₁⁴ − T₂⁴), with σ = 5.67 × 10⁻⁸ W/(m²·K⁴). The fourth power on the kelvin temperatures is why a kiln wall glows and a radiator at 60 °C is merely warm.

Q̇ is a power, in watts. Divide by area and you have the heat flux φ in W/m². A large thermal resistance is how you make that flux small — which is the whole point of insulation, and of not putting a bare copper pipe through a cold loft.

A real wall: resistances in series

To leave a heated room, heat has to cross an inner air film, then the solid, then an outer air film. Those three resistances add, the same way electrical resistances add in series. Surface resistances are 1/hᵢ and 1/hₑ, in m²·K/W. The slab in the middle is e/λ, in the same unit. The U-value is the reciprocal of that sum: one number for the whole wall.

Rsurf = 1/hᵢ + e/λ + 1/hₑ · U = 1 / Rsurf · Q̇ = U · A · ΔT

Small U, good insulation. A bare brick wall might sit around 2 W/(m²·K). A modern cavity with 100 mm of mineral wool aims nearer 0.3. The stacked bar in the result panel tells you which of the three terms is actually doing the work. On a thin steel panel, the air films dominate and doubling the metal thickness does almost nothing. On a 200 mm wool quilt, e/λ is the story and the films are a rounding error.

Insulation: what λ and thickness actually change

Fourier is linear in 1/e. Twice the thickness, half the conduction — if λ stays put. That is why loft insulation is sold in millimetres, not in good intentions. λ itself is the material. Expanded polystyrene ≈ 0.035 W/(m·K), glass wool ≈ 0.040, timber ≈ 0.15, brick ≈ 0.84, glass ≈ 1, steel ≈ 50. A centimetre of wool beats a centimetre of brick by a factor of twenty.

There is a catch. Make a wall so insulating that the air films no longer matter, and further thickness still helps, but the U-value curve flattens: you are fighting 1/h as well. The wall mode on this page shows that flattening. The conduction-only mode does not, because it pretends the surfaces are perfect contacts.

Radiation: why T⁴, and what emissivity is doing

Every body above 0 K radiates. A black body (ε = 1) radiates σ T⁴. A real surface radiates ε σ T⁴, and also absorbs with the same ε (Kirchhoff, at a given wavelength). Net exchange between a body at T₁ and a large enclosure at T₂ is ε σ A (T₁⁴ − T₂⁴). The fourth power is brutal: 373 K versus 293 K is not a 27 % bump, it is (373/293)⁴ ≈ 2.6 on the T⁴ term.

  • Matte paint, brick, glass, skin: ε around 0.9 to 0.98. They radiate almost like black bodies in the infrared, whatever colour they look to the eye.
  • Polished aluminium: ε ≈ 0.05. A foil survival blanket, a Thermos jacket, a low-E coating on glazing — all of them are playing this number down.
  • T must be kelvin. 20 °C into T⁴ as “20” is not a small error. It is a fantasy.

A domestic radiator is mostly convection plus some radiation. A night sky over a clear roof is a cold T₂, which is why a windscreen frosts even when the air is a degree above zero. This page's radiation mode is that net T⁴ exchange, not a view-factor circus between ten surfaces.

From the U-value to the heat loss of a house

Once you have U, the steady loss of a fabric element is U · A · ΔT. A 20 m² wall at U = 0.30 W/(m²·K), 20 °C in and 0 °C out: Q̇ = 0.30 × 20 × 20 = 120 W. Not a heater, a trickle. The same area of single glazing at U ≈ 5.5 is 2.2 kW. That is why windows eat the heating bill, and why a U-value on a datasheet is worth reading before you buy the glass.

Add the other walls, the roof, the floor, and a ventilation term, and you have a crude heat-loss calculation. This calculator does one element at a time. Thermal bridges — lintels, party-wall junctions, a steel balcony — punch holes in that one-dimensional picture. They do not show up in e/λ for the plain wall.

Typical h values, and when convection takes over

h is the sloppy coefficient. It hides geometry, fluid, speed, turbulence, and whether the surface is hotter or colder than the air. Orders of magnitude, not lab certificates:

  • Still indoor air, vertical wall: 5 to 10 W/(m²·K).
  • Outdoor air with a breeze: 20 to 50.
  • Water, natural: a few hundred. Forced flow in a pipe: 1,000 to 10,000.
  • Condensing steam on a clean tube: 10,000 and up, until the film of condensate thickens.

A heat exchanger lives or dies on h, not on λ of the metal — the wall is thin and copper is already generous. A loft hatch lives or dies on e/λ of the quilt. Same three modes, different bottleneck. If you are sizing the energy to heat a tank of water, this page tells you how fast that energy then leaks away through the jacket.

Results are for the steady state (temperatures no longer drifting) and for one-dimensional flow through a plane wall. Thermal bridges, moisture, transients, and the coupling of the three modes are left out. Treat the numbers as an order of magnitude, not a SAP worksheet.