Hydraulic Cylinder Force & Speed Calculator
A double-acting hydraulic cylinder pushes and pulls using fluid pressure applied to both faces of its piston. Those two faces don't have equal area: on the cap (blank) side, the full piston area does the work; on the rod side, the rod itself takes up part of the area — the annular area. At equal pressure and flow, a cylinder therefore pushes harder than it pulls, but it retracts faster than it extends.
Enter the supply pressure, the bore (piston diameter), the rod diameter and the flow rate delivered by the pump: the calculator gives force and speed in both directions.
Pressure, geometry and flow rate
Hydraulic terms marked with an asterisk are defined in the glossary.
Single-acting vs. double-acting cylinders: when a return spring is enough
A single-acting cylinder* has one port. Oil pushes one way, and that is the lot. Return is a spring, the weight of the load, sometimes a gas strut. One hose, one fitting, fewer rod seals — cheaper, and fewer places to leak.
Two ports, one each side of the piston, make a double-acting cylinder*. Extension and retraction are both powered — press, excavator boom, table slide.
The two faces are not equal. The cap end, on extension, sees the full bore πD²/4; the rod end, on retraction, is left with the annular area* π(D² − d²)/4. At the same pressure* the cylinder pushes harder than it pulls. Deliberate. That is why this page prints two forces.
Fext = p × πD² / 4 · Fret = p × π(D² − d²) / 4
Each face is F = p·A at the oil pressure on the piston, not a standing liquid column (hydrostatic pressure).
A spring, or gravity, is enough for a skip body that falls back on its own, a bottle jack, a hydraulic clamp, a stop pusher. Once the load will not bring the rod home, or a pull is required, the cylinder is double-acting. Quite a few “single-acting” rams on plant are telescopic tipper cylinders. Gravity does the rest.
Telescopic cylinders: multiple stages for a long stroke in a short envelope
Three tubes nested, all home: total stroke is the sum, closed length barely more than one stage. Tipper, tail-lift, lorry crane.
Each stage has its own bore. The largest leaves first — pressure sees the biggest area, and the biggest force. The next stage follows, and then the smallest. Force falls as the ram opens, often just as the dump-body lever arm is shrinking. Convenient geometry, and not always true.
A tail-lift at the end of its travel can still want torque. This calculator treats one stage at a time; each diameter is re-run at the same p and the same flow*.
The catch: a single-acting telescopic ram comes home only if the load pushes. Empty, or a platform lying flat, it can sit out. Hence the rarer, dearer double-acting telescopics, with a powered return.
End-of-stroke cushioning and shock loads on light loads
At the end of the stroke the piston hits the cap. With no cushioning*, the stop is a bang, a noise, a seal that ages in a hurry. Industrial cylinders swallow the last few millimetres with a restriction — a spear, a groove, a cushion that throttles the outlet. Pressure builds locally, the piston eases down, and it sits.
On a heavy load that works. On a light one — empty table, guide ram, rod running horizontal — the throttle can be too fierce.
Fluid is trapped, pressure spikes, the rod jerks. The cushion screw is backed off, or a bypass check is fitted. A cushion set for 50 kN is not a cushion for 2 kN. Shocks come from elsewhere too: air in the circuit, a valve that cracks open too fast, a load that “lets go”. End-of-stroke cushioning only treats the hit against the cap. Not the rest.
Rod buckling on long-stroke cylinders (an analogue of Euler buckling)
A long rod in compression, extending under load, is a column. It can buckle long before the compressive stress σ = F / (πd²/4) goes anywhere near yield — Euler again.
Fcrit = π² E I / Lk² · I = π d4 / 64
E is steel, about 210 GPa. I is the second moment of the round rod. Lk, the effective length, depends on the ends: clevis both ends, Lk is roughly the extended length; a fixed cap shortens it. Catalogues and ISO charts give stroke / bore / rod combinations. A 50/28 at 800 mm stroke, in compression, is a discussion; the same ram in tension is not.
Three usual remedies, often stacked: a fatter rod (I grows with d4, which is brutal), a shorter stroke, an intermediate guide.
Side load — a rod in bending, a misaligned clevis — wrecks the Euler number, which assumes a purely axial force. A cylinder is not a beam. If the rod is taking shear, the mounting is wrong.
Working pressure, safety factor and proof-test pressure
Working pressure is what the gauge shows all day. 160, 210, 250, 350 bar, depending on the range. The cylinder maker stamps the value on the nameplate. Above it, seals wear and the duty leaves the buckling chart.
Proof pressure* is a factory test: often 1.5 times working pressure, a few minutes, looking for a weep. Burst is not the point. Tubes are sized with a factor of about 3 to 4 on material strength, to swallow spikes — valve slam, end of stroke, a jammed load. A water-hammer peak at twice working pressure is not a camp-fire story. Hence relief valves, accumulators, the right hose class.
Pproof ≈ 1.5 × Pworking · Pburst ≈ (3 to 4) × Pworking
F = p × A uses working pressure, not proof. Proof checks the tube and does not license operation at 1.5 p. Line loss is separate: pipe head loss.
Standard symbols (ISO 1219) for a cylinder on a hydraulic schematic
On a schematic the cylinder is not a cutaway. ISO 1219-1 draws a rectangle, a rod, one or two ports. Single-acting: one port, often a spring drawn opposite. Double-acting: two ports, one each side of the piston. Through-rod, telescopic, cushioned: each has an extra mark — a small extra rectangle, a nest of tubes.
Ports are labelled cap and rod, sometimes A and B, sometimes P1 / P2 as on this page. The symbol gives the role, not the bore. Diameters come from the catalogue, or from this calculator. Reading a circuit without ISO 1219 is guesswork; with the standard, the oil path runs from pump displacement to the rod.
Sizing bore and rod from a spec sheet (target force and speed)
Four numbers, in order: peak force, stroke, wanted speed, available pressure. Without a pressure the bore cannot be sized: A = F / p.
- Cap-end area: Ac = Fext / p, then D = √(4Ac / π). Next catalogue bore (40, 50, 63, 80, 100, 125 mm…).
- Rod: typically 0.5 to 0.7 × D. Fatter if buckling looms; slimmer where pull force and a snappy extend both matter.
- Fret = p × π(D² − d²)/4. Where the pull matters, a smaller d may be forced — or more bar.
- Flow: Q = v × A. Cap and rod areas differ: the same Q gives two speeds, and the same speed wants two flows.
A 50/28 at 200 bar pushes at 39 kN and pulls at 27 kN. A pull of 35 kN is the wrong pair, or the wrong pressure. The catalogue has the last word: the figures prepare a supplier call and do not replace the standard series.
Worked example: baler cylinder, dump-truck tipping cylinder
Baler, double-acting. The duty is 200 kN at 200 bar (20 MPa). Cap-end area is A = 200,000 / 20,000,000 = 0.010 m², giving D = 113 mm. Catalogue: 125 mm bore, rod 70 mm.
Ac = π × 125² / 4 = 12,272 mm² · Ar = π(125² − 70²)/4 = 8,425 mm²
Fext = 245 kN · Fret = 168 kN (at 200 bar)
Extend at 20 mm/s: Q = 0.020 × 0.01227 = 2.45×10−4 m³/s, i.e. 14.7 L/min. Retract, same flow, runs at 20 × 12,272 / 8,425 ≈ 29 mm/s.
Faster, and weaker. Everyday double-acting behaviour.
Tipper, single-acting telescopic. Largest stage: 200 mm bore, 210 bar, peak force 659 kN, around 67 tonnes — plenty to start a 15-tonne body, the lever arm not being 1. Open stroke 1.2 m, closed 0.5 m.
Weight brings it home. No need for double-acting. A bottle jack or shop press is the same single-acting idea: oil pushes, and the load (or a spring) looks after the return.
Why a cylinder retracts faster than it extends
Same pump, same flow Q. The rod-end area is smaller, so v = Q/A is larger. Not a fault. Geometry. The speed ratio is exactly Ac / Ar = D² / (D² − d²).
A 50/25 gives about 4/3 ≈ 1.33. A 50/36 (fat rod, anti-buckling) climbs towards 2. Retraction rushes, extension crawls.
Where both times must match, two flows are required — a flow control, a divider, or a pump that does not deliver the same Q both ways. The calculator prints both speeds for that reason, not as decoration. Hose speed is v = Q/A again, on the flow, velocity and pipe diameter page.
Mountings and side load: a cylinder is not a beam
Clevis both ends: the ram should see axial load only. Trunnion, flange, front nose, tube clamps — each mounting changes Lk and the moment the rod can take. A few millimetres of clevis offset and the rod bends every stroke. Seals hate it. The rod hates it.
Side loads belong on an external guide (slides, a linkage, a radius arm), not on the gland. A steer ram on a mini-digger has a pin meant for that; a press ram does not.
Polish on one side of the rod only? The mounting is at fault, not the diameter.
From pump flow to stroke time
Speed v = Q / A flips to time: t = stroke / v = (stroke × A) / Q, chamber volume over flow. A 500 mm stroke on an 80 mm bore, at 20 L/min, extends in about seven and a half seconds. Retract is quicker at the same flow.
Flow comes from pump displacement and speed, Q = Vg × N, slip aside. No pump in the sizing is a 2 hp motor on a tipper: displacement and torque there, motor size on the pump power calculator.
Rod seals, filtration and service life
The rod goes out, picks up grit, and comes home. Wiper and rod seal do the job if the oil stays clean. Filtration of 10–20 µm (ISO 4406) changes life more than knocking 20 bar off the gauge. A scored seal weeps first, jets next, and the rod pits.
Chrome flaked, rod bent, or boot torn: the rod is replaced, not just the seal. A hose short enough to yank the fitting at every full stroke is another way to empty the tank on the floor.
Glossary
- Single-acting cylinder
- One port. Oil drives one direction; a spring, the load, or a gas strut returns the rod.
- Double-acting cylinder
- Two ports, one each side of the piston. Both extension and retraction are powered: full bore on the push, annular area on the pull.
- Annular area
- Rod-side area π(D² − d²)/4. Lower retract force and, at the same flow, higher retract speed than the cap.
- Pressure
- Oil force per unit area on a piston face. F = p·A uses working pressure on that face, not proof pressure.
- Flow
- Oil volume per unit time, Q. Speed is v = Q/A. Pump delivery is Q = Vg × N, slip aside.
- Proof pressure
- Factory hold, often 1.5 times working pressure for a few minutes, checked for a weep. Burst margin is about 3 to 4 times working pressure.
- Cushioning