Heating a body means giving it energy. The sensible heat is the part that changes its temperature (with no change of state): Q = m·c·ΔT. Work out the energy required — and how long it takes for a given power — or the final temperature when two bodies are mixed together.

“Sensible” is the opposite of “latent”: here the temperature changes, with no melting or boiling. The specific heat capacity c is the energy (in joules) needed to raise 1 kg of a material by 1 °C. Water, at c ≈ 4,186 J/(kg·K), is famously hard to heat.

Case and inputs

Type of calculation

Switch situation, then run the calculation again to update the fields.

Heating energy

For water, 1 L ≈ 1 kg.

If given, the ideal time t = |Q| / P is estimated.

Result

  • Energy to supply 334,880 J
Mass m 1.000 kg
Specific heat c 4,186 J/(kg·K)
Initial temperature T₁ 20.00 °C
Final temperature T₂ 100.00 °C
Temperature change ΔT 80.00 °C (= 80.00 K)
Energy Q 334,880 J
Energy Q 0.0930 kWh

Q = m · c · (T₂ − T₁) t = |Q| / P

Sensible heat: the energy of a temperature change

Warm something up and you have to pay in energy. For a mass m, a specific heat capacity c and a temperature rise ΔT, the bill is Q = m·c·ΔT. That is sensible heat: you can sense the temperature move. c is how stubborn the material is — joules per kilogram per kelvin. Water is a mule. Copper is not.

ΔT is a difference, so the number is the same in °C and in kelvin. 20 to 80 °C is 60 K of rise. Absolute temperature only matters when you start taking ratios, as on the entropy-change page. Here, a gap is a gap.

Q = m · c · ΔT · P = Q / t · t = Q / P

Why water is in a league of its own

Liquid water sits at about 4,186 J/(kg·K). Aluminium is around 900, iron around 450, air (at constant pressure) around 1,005. Same mass, same ΔT: water swallows roughly five times the energy of aluminium and eleven times that of iron. That is why a kettle takes its time, why a car engine dumps heat into a water jacket rather than into a block of steel, and why a central-heating loop is full of water and not oil if it can help it.

The oceans are the same trick at planetary scale. A lot of heat goes in, the temperature barely budges, and the climate stays less savage than a dry rock at the same latitude would be. Ice, by the way, is only about 2,060 J/(kg·K) — still high, but not liquid-water high. Once it melts, you have paid the latent heat as well, which this formula does not see.

From energy to time: power

A heater delivers a power P, in watts — joules per second. The optimistic time to push energy Q into the load is t = Q / P. Reality is slower: heat leaks, the element is not 100 % efficient, and the last few degrees always take longer than the first few.

  • Kettle — 1.5 L of water, 20 to 100 °C: Q ≈ 502 kJ. A 2,000 W element: t ≈ 251 s, a little over four minutes if nothing escaped. A real kettle is more like five, because the body warms up too.
  • Hot-water cylinder — 200 L from 15 to 60 °C: Q ≈ 37.7 MJ ≈ 10.5 kWh. An immersion at 2,400 W wants about 4 h 20. That is why off-peak Economy 7 still makes sense on a tank that size.
  • Cooling — T₂ < T₁ and Q comes out negative. Same formula, opposite sign: the energy you must remove. A fridge, an air conditioner, a quench tank. The COP of the machine then decides how much electricity that removal actually costs.

The equilibrium temperature of a mixture

Two bodies, different temperatures, thrown together in an insulated box. Heat flows until they share one temperature. If nothing leaks, every joule the hot one loses is a joule the cold one gains. That is the calorimeter idea, and it rearranges to a weighted average of the two heat capacities m·c:

T_eq = (m₁ c₁ T₁ + m₂ c₂ T₂) / (m₁ c₁ + m₂ c₂)

The bigger m·c dominates. A cold teaspoon in a pan of soup does almost nothing to the soup; the soup has the heat capacity. Drop a hot steel bolt into a cup of water and the water barely warms — steel's c is modest, and there is not much mass of bolt. Swap the roles (a lot of hot metal, a little water) and the water can flash toward boiling. The formula does not care which way around; it just weights.

cp versus cv

Gases have two common specific heats. Heat at constant pressure (cp) and the gas is allowed to expand: part of the energy does work, so you need more heat for the same ΔT. Heat at constant volume (cv) and all of Q goes into internal energy. For an ideal gas the gap is R per mole: cp − cv = R/M on a mass basis.

The “Air (const. P)” preset on this page is cp ≈ 1,005 J/(kg·K), the number you want for a room being warmed at atmospheric pressure. A rigid pressure vessel is cv, about 718 J/(kg·K) for air. Solids and liquids barely change volume, so the distinction is academic and one c is enough.

A real calorimeter is not a perfect flask

School calorimetry pretends the cup has no heat capacity and no losses. A real polystyrene cup has both. The usual patch is an equivalent mass of water for the vessel, mcal, measured once with a known hot sample, then added to the cold-water side of the energy balance. Skip that and your c comes out low: some of the heat went into the cup and you blamed the sample.

Stirring, a lid, and not waiting ten minutes for the last 0.2 °C all matter more than the fifth significant figure on c. This calculator is the ideal balance. Treat the result as the energy in the substance, then add the kit and the leaks if you are sizing a heater.

Latent heat: what Q = m·c·ΔT does not see

Cross a change of state and temperature stalls. Ice at 0 °C drinks about 334 kJ/kg before it becomes water at 0 °C. Water at 100 °C drinks about 2,260 kJ/kg before it becomes steam at 100 °C. None of that is in m·c·ΔT, because ΔT is zero while the phase change runs.

Heat 1 kg of ice from −10 °C to steam at 100 °C and you pay three chunks: sensible in the ice, latent of fusion, sensible in the liquid, latent of vaporisation. The middle two dwarf the first. If the interval you typed on this page crosses 0 °C or 100 °C for water, the number it prints is only the sensible part — and it is the wrong number for a kettle that actually boils dry.

The calculation assumes no change of state over the interval, a constant specific heat, and a perfectly insulated enclosure (no losses, no heat capacity of the vessel). Melting or boiling needs latent heat on top. To track the disorder that heat produces, use the entropy-change calculator.