Convert Resistors: Star (Y) to Delta (Δ)
Kennelly's theorem replaces a network of three resistors in star (each tied to a common center N) with an equivalent network in delta (tied pairwise) — or the reverse — without changing the behaviour seen from the three terminals 1, 2, 3. It's the basic tool for simplifying an unbalanced three-phase load, or for comparing a star-wound motor with its delta equivalent.
The known network
Why star and delta are electrically equivalent as seen from outside
Three resistors in a Y, three in a triangle: they look nothing like each other on the bench. From the three terminals, they can be made to look identical. Same resistance between 1 and 2, between 2 and 3, between 3 and 1. If an external circuit cannot tell which network is behind those three screws, the two networks are equivalent. That is all Kennelly's theorem claims — not that the insides are the same, only that the port behaviour is.
Currents inside the two figures are not the same. Voltage from a star point to a vertex has no delta counterpart (there is no star point). Equivalence stops at the terminals. Pull a current internally and the trick is over.
Deriving the formulas from the equal-resistance condition between each pair of terminals
Leave terminal 3 open. In the star, R12 seen from outside is Ra + Rb. In the delta, it is R12 in parallel with (R23 + R31). Set those equal, write the same for the other two pairs, and solve. After a page of algebra you get the two classic sets:
Star → delta: R12 = (Ra·Rb + Rb·Rc + Rc·Ra) / Rc
Delta → star: Ra = R31·R12 / (R12 + R23 + R31)
The pattern is the thing to remember. Star to delta: each side of the triangle is the sum of the products of the star legs, divided by the opposite leg. Delta to star: each star leg is the product of the two delta sides that meet at that vertex, divided by the sum of all three sides. Vertex and opposite side. Mix them up and the numbers still look plausible — they are just someone else's network.
Symmetric case: Ra=Rb=Rc gives a delta at 3×Ra (and the reverse, ÷3)
If the three star legs are equal, the formula collapses. R12 = (Ra² + Ra² + Ra²) / Ra = 3 Ra. Each delta side is three times a star leg. Going the other way, each star leg is a third of a delta side. That is the number everyone remembers, and the one that is wrong the moment the three values are not equal.
A balanced three-phase load is this case. An unbalanced one is not — use the full product formula, not a casual ÷3. This calculator will happily do the unsymmetric job; the ÷3 is only a sanity check when you typed the same value three times.
Application: simplifying an unbalanced three-phase load
Three heaters in delta, different wattages, fed from a three-phase supply with no neutral. You want the line currents. Convert the delta to a star, and each line now sees one equivalent resistor to a fictional star point. The three line currents follow at once (they will not add to zero if the load is unbalanced — there is no neutral to carry the residual, so the star-point voltage of the equivalent network shifts). Convert back if you then need the current in a particular heater: that current lives in a delta side, not in a star leg.
The same move works for a mixed load: a motor in star plus a heater bank in delta. Put everything into one figure, combine parallels, transform, reduce. That is circuit analysis, not motor starting.
Star-delta starting of induction motors: what it actually changes
Different page, same words. Motor star-delta starting is a reconnection of windings so that each coil sees U/√3 instead of U, which cuts line current and torque by three. It is not Kennelly. You are not replacing a network by an equivalent one; you are changing the voltage on a real winding. The star-delta motor starting calculator is the tool for that. This page will not tell you whether a compressor will start.
The shared vocabulary is a historical nuisance. Electricians say “star-delta” for both. One is a theorem about resistors. The other is a starter. Keep them in different drawers.
Using the transform to simplify a complex resistive network (bridges, ladders)
A Wheatstone bridge that is not at balance is the textbook excuse. You cannot series-parallel your way through the crossing arm. Transform one of the triangles (or one of the stars) into the other figure, and the crossing arm disappears into series-parallel pieces. Ladders with a delta in the middle yield the same way: one transform, then a chain of series and parallel reductions down to a single Req.
Do it by hand once so you trust the formula. After that, this page is the arithmetic so you do not drop a product on the way.
Generalizing to complex impedances (AC circuits)
The derivation never used “resistance”, only the ratio V/I at a pair of terminals. Replace every R by a complex Z (jωL, 1/jωC, a series combination) and the same two formulas hold. You add, multiply and divide in the complex plane. A delta of capacitors, a star of inductors, an unbalanced R–L load: all fair game. What you cannot do is treat a non-linear element (a diode, a saturable inductor) as a Z and transform it. Kennelly is linear network theory.
At a single frequency the complex form is exact. Over a band of frequencies each Z moves, so the equivalent has to be recomputed. There is no single R–L–C star that matches a given delta at every frequency unless the original network was already that simple.
Common mistakes: mixing up the vertex and the opposite side in the formulas
Ra sits at vertex A, opposite side R23. R12 sits between vertices 1 and 2, and the star leg that does not touch that side is Rc. The formula R12 = (sum of products) / Rc is “divide by the leg that faces that side”. Divide by Ra instead and you have assigned the 12-side to the wrong vertex. The three numbers you get will still be positive and dimensionally ohms. They will just belong to a different labelling.
- Sketch the two figures and write the labels on the paper, not in your head.
- Star → delta: divide by the opposite leg. Delta → star: product of the two sides that meet at the vertex.
- If the three values were equal, check the 3× or ÷3 sanity result before you trust an unsymmetric case.
Measuring a physical delta to recover the star
A three-terminal component (a three-phase heater bank with no accessible star point) can still be modelled as a star. Measure R12, R23, R31 with a low-ohm meter, type them in as a delta, and read Ra, Rb, Rc. Useful when a simulation wants a wye, or when you need the current in a notional leg. The measurement has to be off-supply, and any fourth wire (a real star point brought out) means you should measure the legs directly instead of transforming.
What the theorem does not claim
No sources inside the triangle, no mutual inductance that is not already absorbed into the Z's, no “earth” that is not one of the three terminals. Add a source between the star point and earth and the equivalent delta has nowhere to put it — you would need an extra port.
A quick numerical habit
After a transform, the order of magnitude should make sense: the equivalent delta sides are larger than the star legs in the symmetric case (3×), and they stay in the same neighbourhood when the three values are only mildly unbalanced. If Ra was 10 Ω and R12 comes out at 10 kΩ, a label or a keystroke went wandering.
This page is Kennelly's resistor (or impedance) transform. It is not a motor starter, not a three-phase power calculation, and not a permit to replace a live winding connection with an “equivalent” one. For line current and power factor on a balanced supply, use the three-phase power calculator.