Solar Panel Output & Sunlight Calculator

How much electricity can a solar array really produce? It depends first on the sunlight received — which varies with location, season, orientation and tilt of the modules — then on how the panels convert it into electricity. This calculator chains the two: it estimates the irradiation captured in the plane of the modules, then the power and energy produced, per square metre and for the whole array, on a daily, weekly, monthly and yearly basis.

Once the form is filled and submitted, the detailed results, monthly tables and charts update. Notes at the foot of the page explain each quantity and the method used.

The values shown below are an example (Paris, 20 m², due south, 30° tilt). Change the fields to match the installation under study.

The installation

Location

Each place provides an indicative monthly-average irradiation.

Positive = northern hemisphere. Used if "manual entry".

Daily average on a horizontal surface ("GHI"). Used if "manual entry".

Panels

Recent modules: 19 to 22 %. About 200 Wp per m² at 20 %.

Orientation and tilt

Due south = optimal in the northern hemisphere.

0° = flat, 90° = vertical. Estimated optimum here: 25°.

System and display

Overall system losses (inverter, cabling, temperature, soiling…). Typical: 75–85 %.

Ground reflection: ~20 % (grass/concrete), up to 80 % (snow).

Summary results

Chosen configuration:

Paris (France) 20.0 m² 20.0 % efficiency South 30° tilt PR 78 %
  • Energy produced — year 3,747 kWh/yr
  • Installed peak power 4.00 kWp
  • Productivity (yield) 937 kWh/kWp/yr
  • Irradiation received in the plane 1,201 kWh/m²/yr
  • Orientation gain vs horizontal +7.3 %

Instantaneous peak power (solar noon, June)

QuantityPer m²Whole array (20.0 m²)
Solar power received 625 W/m² 12.50 kW
Electrical power produced 98 W/m² 1.95 kW

For reference, the irradiance of the modules under standard test conditions (STC) is 1,000 W/m²: that is the value defining the peak power (kWp).

Energy per period

Period Solar energy received Electrical energy produced
Day (annual average) 65.8 kWh 10.3 kWh
Week (average) 462 kWh 72 kWh
Month (average) 2,002 kWh 312 kWh
Best month (July) 3,257 kWh 508 kWh
Weakest month (December) 637 kWh 99 kWh
Year 24,020 kWh 3,747 kWh (3.75 MWh)

Output month by month

02505007501,000JanFebMarAprMayJunJulAugSepOctNovDeckWh/month
Electrical energy produced each month (kWh) — the most productive month is highlighted.

Power over a day — June

0.00.51.01.52.04 h6 h8 h10 h12 h14 h16 h18 h20 hkW
Electrical power produced (kW) for a typical day in June, in solar time. The bell widens and rises in summer, narrows and drops in winter.

Monthly detail

Month Horizontal irrad.
(kWh/m²/day)
In-plane irrad.
(kWh/m²/day)
Energy received
(kWh)
Energy produced
(kWh)
January 0.90 1.09 677 106
February 1.60 1.91 1,071 167
March 2.70 3.10 1,922 300
April 4.00 4.28 2,570 401
May 4.90 4.93 3,055 477
June 5.40 5.28 3,169 494
July 5.30 5.25 3,257 508
August 4.60 4.83 2,996 467
September 3.40 3.90 2,338 365
October 2.00 2.43 1,508 235
November 1.10 1.37 820 128
December 0.80 1.03 637 99
Year 1,119 1,201 24,020 3,747

The first two columns are daily averages; the "energy" columns add up over the whole month.

Effect of tilt

At a fixed orientation (South), here is the estimated annual output for several tilt angles. The optimal tilt for this location is about 25°.

TiltAnnual output (kWh)Gap to maximum
0° 3,492 -6.8 %
15° 3,697 -1.4 %
25° (optimal) 3,748 0.0 %
30° 3,747 0.0 %
45° 3,640 -2.9 %
60° 3,381 -9.8 %
90° 2,498 -33.4 %

A few equivalences

  • Households powered (elec. excl. heating) 0.8 household(s)
  • CO₂ avoided (EU-mix substitution) 1,124 kg/yr
  • Distance in an electric vehicle 22,042 km/yr

Indicative assumptions: household ≈ 4,700 kWh/yr (excl. heating); 0.30 kg CO₂/kWh (average European grid mix substituted); 0.17 kWh/km. These orders of magnitude vary widely by situation.

Solar shorthand marked with an asterisk is spelled out in the glossary below.

Irradiance, irradiation and peak power (kWp)

Irradiance* is a power, right now, in watts per square metre. Clear sky, solar noon, a square-on surface: something close to 1,000 W/m². That is a snapshot, not a harvest.

Irradiation* (solar exposure) is the energy that snapshot adds up to over a day or a year, in kWh/m². Same place, same roof: 2 kWh/m² on a December day, 7 kWh/m² in June is a perfectly ordinary temperate-climate swing. Irradiance is integrated over time. The calculator’s monthly columns are that integral, not a brighter sun.

Mix the two units and an inverter gets sized on a daily energy figure, or a battery on a noon spike. They are cousins. They are not the same quantity.

Peak power* (kWp) is the module’s output under standard test conditions: 1,000 W/m², cell at 25 °C, AM1.5 spectrum. For a given area, peak power ≈ area × efficiency, because 1,000 W/m² is 1 kW/m². A 20% module is therefore about 200 Wp per square metre. The sticker on the back of the panel is that number, not what the roof did last Tuesday. How much of that 1,000 W/m² actually arrives through the atmosphere is the atmospheric attenuation page’s job.

Annual energy then has a neat shortcut: equivalent sunshine hours — how many hours at 1,000 W/m² would deliver the same irradiation. Numerically that count equals the in-plane irradiation in kWh/m². Hence:

energy ≈ peak power × equivalent hours × PR

A 4 kWp array, 900 equivalent hours, PR 0.78: about 2,800 kWh. That is the same arithmetic as Hplane × S × η × PR, just grouped differently. Use whichever grouping matches the datasheet in front of the form.

Orientation and tilt

A panel wants the beam head-on. Two settings decide how often it gets that.

  • Orientation (azimuth). In the northern hemisphere, due south maximises the year. Swing east or west and the peak moves within the day, shaving a little off the total — often only a few percent out to ±45°. A due-east roof is not a disaster. A due-north roof is a different conversation.
  • Tilt. Flat (0°) favours summer. Near vertical favours winter, when the sun is low. The annual optimum sits around the local latitude — 30° to 40° for most of the UK, which is what the sensitivity table above is for.

The curve around that optimum is flat. A roof that forces 15° or 45° usually costs a few percent, not a third of the year. That is the number the calculation is there to pin down; the argument with the tiles can then stop.

Shading is not a few percent. A chimney on a winter morning can take a string out. This page does not model that. A surveyor should.

From global horizontal irradiance to the plane of the array

The calculation starts from monthly global horizontal irradiation (indicative figures for the place picked, or the annual average typed in). Then it rebuilds what the modules actually see, in four steps.

  1. Splitting the day into hours. The daily total is spread hour by hour with the Collares-Pereira & Rabl model — a bell centred on solar noon.
  2. Direct / diffuse split. Each hour is broken into beam from the solar disc and diffuse from the rest of the sky, using the Erbs correlation and the clearness index.
  3. Transposition onto the tilted plane. Direct is projected by the angle of incidence (Duffie & Beckman). Diffuse uses Hay-Davies: a circumsolar bit that travels with the sun, plus an isotropic bit from the rest of the sky, plus ground reflection (albedo).
  4. Conversion into electricity. In-plane irradiation × module efficiency × performance ratio.

Eyr = Hplane × S × η × PR

Eyr is annual energy (kWh), Hplane the in-plane irradiation (kWh/m²/year), S the area, η the module efficiency, PR the performance ratio. The solar energy received, before conversion, is just Hplane × S. The hourly rebuild is why a 30° south array in January can beat a flat roof even though the horizontal GHI looks miserable — more beam is caught, more of it is not glancing off.

Limits of this estimate

This calculator gives educational orders of magnitude, not a sizing study and not an MCS estimate that can be taken to a lender.

The main limits, in the order they bite:

  • Monthly irradiation values are indicative averages. A real year wanders, and a local microclimate (a sea haar, a mountain shadow, a valley fog) can move the answer more than a 5° tilt change.
  • Near shading — trees, chimneys, the neighbour’s dormer — is not modelled and can wreck a string.
  • Hay-Davies is an approximation. It does not finely paint horizon brightening or every half-cloudy sky.
  • Orientation labels assume the northern hemisphere (0° = due south). South of the equator, the compass is flipped.
  • The equivalences (households, CO2, kilometres) sit on assumptions that vary by country and by how the house is heated.

For a real project, have the estimate confirmed on site, with a shading survey and a proper irradiation dataset. This page is how to learn which inputs matter. It is not the quote.

Export, the Smart Export Guarantee and self-consumption

The Feed-in Tariff closed to new applications in 2019. What remains for a household or a small business is the Smart Export Guarantee*: an obligation on the large suppliers to pay something for kWh exported. The rate is the supplier’s to set. It is not a generation tariff. Payment is for what leaves the meter, not for what the panels made.

This calculator does not know the export fraction. Self-consumption on a house that is empty on a sunny weekday can be 20% to 30% of generation; a heat pump and a weekday-at-home pattern can push it much higher. SEG pays the export, not the self-consumed kWh. The self-consumed kWh are worth the retail rate, which is why they are the ones that pay for the array.

A unit rate around 26p and an SEG rate of 15p is a common shape in the mid-2020s. Every kWh used on site is then worth almost twice an exported kWh. Shifting a wash, a charge, or a heat-pump tank into solar hours is the domestic version of that arithmetic.

kWh per kWp from north to south of the UK

The figure installers quote, and the one MCS paperwork lives on, is kWh per kWp per year. For a south-facing UK roof at 30° to 40°, an honest band is about 800 to 1,100 kWh/kWp. The south coast and the Channel Islands sit at the top; western Scotland’s coast can surprise; a north-facing suburban roof in Manchester will not.

Paris is on the form as a default because the dataset is there — and at 48.9° N it is not a bad stand-in for the south of England. London is a little gloomier than a Provence figure would suggest, and a lot brighter than a brochure photographed in June. Type Lille for something closer to Manchester or Glasgow on latitude; type Nice only if the array is actually there.

A 4 kWp domestic array at 950 kWh/kWp is about 3,800 kWh a year, before anyone argues about the kettle. Ofgem’s typical household electricity use (the medium TDCV, excluding heat) is in the same neighbourhood as that number, which is why a well-aimed 4 kWp system is the cliché on British roofs. It is a cliché because the arithmetic works, not because every roof is south and unshaded.

Dirt, snow and shade versus the performance ratio

Module efficiency is the fraction of radiation that becomes electricity at the cell — around 19% to 22% on a recent panel, 20% if a round figure is wanted. The performance ratio* then bundles everything the datasheet pretends is not there: a hot cell (hot cells make less), the inverter, cabling, soiling, shade, mismatch between modules, a few days offline.

A PR of 0.78 means the installation delivers 78% of what perfect, cool, clean modules at their nominal efficiency would have made. Typical systems sit in the 75% to 85% band. A 0.95 PR on this form is a dare, not a design.

Dirt, lichen and bird muck are inside that PR if the figure came from a monitored year. They are not, if 0.80 was typed because a brochure said so. Snow on a 15° roof in the Highlands can zero a week. A chimney on a winter morning can zero a string. Neither is a 2% soiling factor. Lower the PR only for the diffuse, year-round losses. Put shade in the site survey, not in a heroic 0.70.

MCS certification and the DNO connection

MCS* (Microgeneration Certification Scheme) is the quality mark. An MCS-certified installer, MCS-certified kit, and an MCS certificate are what SEG requires, and they are what the zero rate of VAT on a qualifying residential installation requires. Without MCS, panels can still be bolted to a barn. The tariff and the tax treatment will be a struggle.

Connecting to the GB grid is not a USB socket. Up to 3.68 kW per phase (16 A) — 3.68 kW single-phase, or 11.04 kW on a three-phase supply — the distribution network operator is notified under G98*, usually after commissioning. Above that, G99 applies before switch-on, and the DNO can require a study, a constraint, or a reinforcement that costs more than the extra panels.

That 3.68 kW line is why many British domestic systems are 3.6 kWp or 4 kWp with a slightly oversized array behind a 3.68 kW inverter. The inverter is the connection. The peak power on this page is the modules. They are allowed to differ; a 5 kWp roof on a 3.68 kW inverter is a common, legal, slightly clipped setup.

A 20 kWp barn system is a G99 conversation, not a bigger version of the kitchen-roof job. Ask the DNO early. This page will happily print the kWh. The network may not accept the kW.

Permitted development, listed buildings and a ground mount

Most rooftop arrays on a house in England are permitted development: not higher than the ridge, not proud of the roof plane by more than a small allowance, not on a listed building without consent, and a conservation area has extra care on a wall that faces the highway. Wales, Scotland and Northern Ireland have their own, similar, versions. The planning portal is the document, not a forum post from 2016.

Ground mounts, solar carports, and anything on a listed building or in a designated landscape usually want a planning application. A farm-scale field array always does. Neighbour objections tend to be about glare and “industrialisation”; the planning officer tends to be about designation, agricultural land grade, and the heritage setting.

A roof that is permitted development can still be a bad solar roof. Planning permission is not a yield. If this page says a north-east 15° array is 25% down on south 35°, that loss does not become acceptable because the tiles were easy.

Zero-rate VAT on a qualifying residential array

Since 2022, a qualifying installation of solar panels on residential accommodation in Great Britain can be zero-rated for VAT, rather than the old 5% reduced rate. The conditions are specific: MCS, a dwelling (or certain residential buildings), and the kit listed in the HMRC notice. A commercial barn, a second-home argument, or a DIY kit bought without an MCS installer can fall out of the relief.

The form on this page does not apply VAT. The kWh it prints are before money. A 4 kWp quote that looked cheap because VAT was assumed at 0%, then arrives at 20% because the building is a workshop, is a different project. Check the notice, not a tweet.

Batteries installed at the same time as the panels may follow the panels into the relief; a battery added years later often does not. That distinction is tax law, not physics, and it moves. The energy arithmetic on this page does not.

A battery does not raise the kWh this page prints

A battery stores kWh that would otherwise have been exported. It does not make extra kWh. The annual generation on the results card is the same with or without a battery. What changes is the split: more self-consumption, less SEG, a round-trip loss of typically 10% to 15%.

Whether that pays depends on the gap between the retail unit rate and the export rate, and on how often the house is empty at noon. A heat pump that can drink midday surplus is a rival to a battery, not a partner by default. Both can coexist. Both should be modelled on the kWh this page already gave, not on a brochure’s “energy independence”.

The tariff comparison page is where those kWh meet a unit rate. Generation first, then the slot they land in, then the battery — that order. Reverse it and the battery is sized on a hope.

Glossary

Irradiance
Instantaneous solar power on a surface, in W/m². A snapshot. Clear-sky noon on a square-on plane is around 1,000 W/m²; a dull British afternoon is a few hundred, or less.
Irradiation
Solar energy received over a period, in kWh/m² (per day, month or year). It is irradiance integrated over time. The monthly columns on this page are irradiation, not a brighter sun.
Peak power (kWp)
Module output under standard test conditions: 1,000 W/m², 25 °C cell temperature, AM1.5 spectrum. It is a laboratory rating, not a roof measurement. Annual energy ≈ kWp × equivalent hours × PR.
Performance ratio (PR)
The fraction of ideal, cool, clean generation that the installed system actually delivers. Typical systems sit between 0.75 and 0.85. The PR folds in temperature, inverter, cabling, soiling, mismatch and downtime — not near shading, which needs a survey.
Smart Export Guarantee (SEG)
The post-FIT obligation on large GB suppliers to pay for exported kWh from a small generator. The rate is the supplier’s. It is not a generation tariff: self-consumed kWh are worth the retail rate, not the SEG rate.
MCS
Microgeneration Certification Scheme. Certified installer, certified kit and an MCS certificate are required for SEG and for the zero rate of VAT on a qualifying residential installation.
G98 / G99
Engineering recommendations for connecting generation to the GB distribution network. G98 is a post-commissioning notice up to 3.68 kW per phase (16 A). G99 is a pre-commissioning application above that, and can trigger a network study.