EN

Pump Displacement Calculator (cm³/rev)

The motor is already chosen and the target operating pressure is known : what's left is the displacement — the volume moved per revolution, in cm³/rev — of the positive- displacement pump to pick off a catalogue. That's the reverse of the usual sizing path (flow and pressure known → power to plan for, see the pump power calculator).

MP, Npump, VgQ, ΔP

Power, speed and target pressure

Parameters

1,500 rpm: a standard 4-pole electric motor on a 50 Hz supply.

85 to 95 % for a piston pump, 80 to 90 % for a gear pump.

How pump displacement is calculated

Q [L/min] = 600 · η · P [kW] / ΔP [bar]

Vg [cm³/rev] = 1000 · Q [L/min] / N [rpm]

The constant 600 comes from the exact conversion between kilowatts, litres per minute and bar : 1 kW = 600 L/min at 1 bar. Displacement follows by dividing the theoretical flow by the rotational speed : it's the volume the pump must move on every revolution to deliver that flow.

Asterisks point to the glossary, on first mention only.

Fixed vs. variable displacement

Displacement* is the oil moved in one turn of the shaft, quoted in cm³/rev. Fix that volume and flow has a single lever: shaft speed. The pump does not manufacture pressure. Pressure appears when the oil meets an obstacle — a cylinder on its stop, a relief valve, a load.

Variable displacement breaks that tie to speed. On an axial-piston pump the swashplate* angle sets the stroke; on a vane pump the cam ring sits offset from the rotor. A smaller angle, or a smaller offset, means less volume per revolution and less flow. The electric motor, or the diesel, can hold a steady 1,500 rpm while delivery follows the actuator.

A fixed pump pays for unused oil in heat. Every litre sent across the relief becomes heat, and the prime mover still has to supply full-displacement torque with the cylinder hard against the stop. A variable unit destrokes, and moves only enough oil to hold pressure. Less heat, often a smaller motor, and a tank that is not asked to swallow a continuous dump. The pump costs more. Cooling costs less.

The control target may be a pressure (a compensator*), a flow, or both together (load sensing*). Hardware, hose layout and heat budget all change with that choice. The figure from this calculator is the maximum displacement: peak flow at the target pressure, on the motor already selected.

Gear, vane or piston pump

The sizing relation is indifferent to pump family. The catalogue is not, and neither is the target pressure. The wrong family means the calculated displacement is missing from that range, or will not survive in it.

  • Gear pump — fixed displacement, low cost, tolerant of rough duty. Typical working pressure 150–250 bar, depending on the series. Overall efficiency often 80–90 %. Noisier, with more flow ripple. Farm machinery, simple power packs, any drive that has to keep turning in the wet.
  • Vane pump — quieter, smoother delivery. Pressure more like 100–180 bar. Built fixed or variable. Less common on mobile machines than it once was, and still the usual choice on machine tools and mid-size presses.
  • Piston pump (axial, occasionally radial) — the high-pressure family, 250–400 bar and beyond, overall efficiency 85–95 %. Also the natural home of variable displacement. Dearer, and stricter about filtration and oil cleanliness. Excavators, compactors, large presses: this family.

Pressure comes first, displacement second. Below about 160 bar a gear pump is the honest match. Past 250 bar the duty sits with pistons. Between those marks the choice is a judgement, and the efficiency entered on the form has to follow the type — 80–90 % for a gear pump, 85–95 % for a piston pump — or the calculated displacement comes out low.

A pump is not a relief valve. A call for 200 bar at the work port needs a data sheet whose continuous rating is at least that high, and whose peak rating sits comfortably above it, often 1.2 to 1.4 times the continuous figure. A unit that only just reaches maximum pressure is a short-life purchase.

Typical drive speed by power source

Flow, displacement and speed stay locked together. The same flow at half the speed needs twice the displacement. The prime mover is not a footnote on the data sheet. It fixes n, and n fixes Vg.

Q = Vg · n · ηvol

A four-pole motor on 50 Hz runs at roughly 1,500 rpm, a shade under that once slip is counted. That speed is the default on the form, and it is what most workshop power packs use. The same motor on 60 Hz sits nearer 1,800 rpm. A two-pole machine doubles the speed, to 3,000 rpm, and halves the displacement required — provided the pump's maximum speed allows it.

Data sheets quote a ceiling, often 2,500–3,500 rpm depending on size. Past that ceiling come inlet cavitation*, wear and noise.

On mobile plant a diesel typically works at 1,800–2,200 rpm, and much slower at idle. A tractor power take-off (PTO) is standardised at 540 or 1,000 rpm. A pump sized for 1,500 rpm on an electric motor is far too small on a 540 rpm PTO, and either oversized or overspeeding on a diesel at 2,200 rpm. The speed that belongs in the form is the speed of that shaft, not a customary round number.

Minimum speed matters as well. Below about 600–800 rpm many gear pumps do not prime cleanly, and volumetric efficiency* drops sharply. Hydraulic motors will crawl. Pumps, in general, will not.

Safety margin on a calculated displacement

The calculator returns the displacement that just meets the figures entered. Catalogues do not sell 27.3 cm³/rev. They sell 25, 28, 32 — or 14, 17, 19, 22, depending on the brand. The size taken is the equal value, or the next one up.

That catalogue step is not yet a margin. Pumps wear, oil heats up, and volumetric efficiency loses a few points over the life of the machine. The motor does not always deliver its full nameplate rating at the shaft once its own efficiency and service factor are included. A further 5–15 % belongs on the displacement, according to whether the circuit has been measured or is only a sketch.

Extra displacement at the same speed means extra flow. The cylinder arrives hard, the relief opens more frequently, and the motor draws more torque. On a tractor PTO that torque can stall the diesel.

One catalogue step up is the practical rule. Multiplying by 1.5 for safety overshoots.

The allowance belongs on displacement, not on the pressure entered. Entering 250 bar because the circuit might reach it, while the real duty is 180 bar, shrinks the calculated displacement: the same power is split between flow and pressure. The pump selected on that basis is too small once the relief sits where the duty requires.

Displacement, torque and pressure

Shaft torque does not depend on speed. Displacement and pressure set it, with efficiency in the denominator.

C = Vg · ΔP / (2π · η)

Vg in m³/rev and ΔP in pascals gives C in N·m. In shop units — cm³/rev and bar — the same relation is C ≈ Vg · ΔP / (62.8 · η). This page also reports C = 9,550 · P / N, the electrical-machine formula for shaft torque from power. The two agree once P, Vg and Q are consistent, which they are on this page.

With motor power fixed, a higher pressure forces displacement down, and flow with it. Shaft torque stays about the same, because power is what sets it. The reverse is the trap. The pump is already bought, the pressure is turned up, torque demand climbs, and the motor trips or stalls. The familiar workshop sequence is a relief wound higher, then a motor that will not start.

The η in the denominator is overall efficiency. Pure hydraulic torque needs only 2π. Bearing, seal and swashplate friction sit on top of that. On a tired pump the extra torque is not a rounding error.

Displacement of a hydraulic motor

A hydraulic motor is a pump driven from the oil side: flow in, rotation and torque out. The relations change sides.

n = Q · ηvol / Vg  ·  C = Vg · ΔP · η / 2π

Displacement means the same thing: volume per revolution. A larger figure gives more torque and a lower speed for a given flow — a gearbox without gears. Winches, wheel drives and mixers take a large Vg where torque at low rpm matters, and a small Vg where shaft speed matters.

Efficiency changes sides as well. On a pump, η cuts the delivered flow and raises the torque the shaft must supply. On a motor, η cuts the torque at the shaft and the speed observed. The 90 % on the pump form does not carry over on its own: a slow radial-piston motor may sit under 85 %, a gear motor around 80 %.

This page sizes a pump. A linear actuator is the subject of the cylinder force and speed calculator. A rotary motor uses the two relations above, starting from the torque and the speed required. Flow comes back out of those figures, and the upstream pump displacement follows from that flow.

How a pressure compensator works

Pressure compensation is the ordinary arrangement on a variable pump. A spool reads outlet pressure and, past a set point (say 200 bar), strokes the swashplate back. Displacement falls until flow matches leakage plus whatever the actuators are taking. Against a dead head, flow drops almost to zero, pressure holds, and the motor only has to cover the losses.

Standby pressure sits a little below the compensator setting, not at zero: a trickle remains for internal leakage and pilot oil. Beside a fixed pump dumping across a relief all day, the heat saving is large. That saving, ahead of full-stroke catalogue efficiency, is why a variable unit is specified.

Load sensing goes one step further. The compensator no longer holds a fixed pressure. It holds a constant margin, typically 14–20 bar, above the highest load pressure, read through a load-sensing line. The pump makes only the pressure the work needs. Heat falls again. There is more pilot hose, and the set-up is more delicate.

None of that changes the maximum Vg that has to be bought. Peak flow is required — every actuator moving together, or the greediest one, depending on the circuit. The compensator destrokes afterwards. Sizing on average flow, on the grounds that the pump is variable, is how the swashplate runs out of angle at the worst moment.

Worked example: pump on a piece of plant

A mini-excavator diesel has 45 kW left at the pump shaft, at 2,000 rpm in the working range. Circuit pressure 250 bar. Axial-piston pump, η = 90 %.

  1. Flow the power will support: Q = 600 × 0.90 × 45 / 250 = 97.2 L/min.
  2. Matching displacement: Vg = 1,000 × 97.2 / 2,000 = 48.6 cm³/rev.
  3. Shaft torque: C = 9,550 × 45 / 2,000 ≈ 215 N·m. The coupling and the PTO housing have to take that torque.
  4. Off the shelf the choice is 50 or 56 cm³/rev, depending on the series. Not 45 — too tight once the oil is hot.

The same 45 kW, now taken from a tractor PTO at 540 rpm, jumps in displacement: Vg = 1,000 × 97.2 / 540 ≈ 180 cm³/rev.

Different pump, different torque (C ≈ 796 N·m). The power-pack pump from the workshop does not belong on that trailed implement.

With the 97 L/min known, the pipework can be sized, and pump power checked the other way — a direct catch for a mix-up of units.

Volumetric vs mechanical efficiency

The form carries one efficiency. The trade splits that figure. Volumetric efficiency, ηvol, is leakage: delivered flow is Q = Vg × n × ηvol. New, the ratio sits at 0.92–0.98 depending on type. Hot, at high pressure, or worn, it falls. Hydro-mechanical efficiency* ηmh is friction. It raises the torque, and with it the power drawn. Overall efficiency is the product of the two.

90 % is a fair figure for a healthy piston pump. 95 % on a ten-year-old gear pump is wishful. Where the right value is uncertain, the lower one is the entry to use. A displacement one size up can be limited later, by a lower speed or a flow limiter. A displacement that is too small has no such remedy.

The pump power calculator runs the other way: known flow and pressure, power to provide. Both pages share the constant 600, because 1 kW = 600 L/min at 1 bar. When the two answers do not meet, efficiency or the units have slipped.

Reading a pump catalogue

Makers list Vg in cm³/rev (sometimes in³/rev), a continuous pressure, a peak pressure, a speed range, a maximum shaft torque, and efficiency curves. The displacement on the page is almost always the geometric figure, not the volume that appears at the outlet. That geometric figure is what this calculator aims at.

Sizes are not shared across brands, even where the same round numbers keep turning up: 10, 16, 22, 32, 45, 56, 71, 90, 125 cm³/rev. The mounting flange has to match — ISO 3019, or SAE A/B/C — and so do shaft diameter and direction of rotation. A 50 cm³ pump that will not bolt to the existing housing is scrap before the shaft has turned.

A volumetric-efficiency curve against pressure and speed is worth more than a single η. At 200 bar and 1,500 rpm a gear pump may already be 8 % short of geometric displacement. Real flow has to be worked out again before the cylinder is sized.

Oil viscosity and internal leakage

Oil is not a footnote. Too thick — a cold start, or a grade that is too heavy — and the pump does not prime: inlet pressure collapses, and cavitation follows. Too thin — hot oil, or a grade that is too light — and the running clearances leak more, ηvol drops, and effective displacement fades. ISO VG 46 at 40 °C is the usual European starting point. Oil sitting at 80 °C is no longer at that viscosity.

Internal leakage grows with pressure and with wear. A pump that runs hot on standby often already has a poor ηvol: a share of the oil returns to the case, not the actuator. Recalculating displacement will not repair that — replacement will, or filtration and temperature put right.

Inlet-line diameter matters as much as displacement. A 50 cm³/rev pump at 2,000 rpm draws roughly 100 L/min, and that flow has to come in without too much vacuum. The flow–velocity–diameter calculator keeps the suction line inside the usual 0.5–1.2 m/s band. Outside it, the best Vg in the catalogue cavitates on the first warm afternoon.

Glossary

Displacement
Volume a positive-displacement pump or motor moves in one shaft revolution, in cm³/rev. The catalogue figure is geometric chamber volume, not outlet volume after leakage.
Volumetric efficiency
Delivered flow divided by geometric displacement times shaft speed. Leakage reduces it; heat, high pressure and wear push it down further.
Hydro-mechanical efficiency
Share of shaft torque that becomes hydraulic torque after friction in the bearings, seals and swashplate. Overall efficiency is this figure times volumetric efficiency.
Pressure compensator
Control on a variable pump that cuts displacement once outlet pressure reaches a set point, so delivery falls to leakage plus actuator demand while pressure holds.
Load sensing
A compensator that holds a margin above the highest load pressure, read on a separate line, rather than a fixed standby pressure.
Cavitation
Vapour cavities in the incoming oil when inlet pressure collapses — thick cold oil, a tight suction line, or speed past the published ceiling. Their collapse damages the pumping elements.
Swashplate
Tilted plate in an axial-piston pump. Its angle sets piston stroke and displacement per revolution. A compensator moves that angle, not shaft speed.

Related calculators