EN

Calculate Stair Dimensions (Rise and Run)

A comfortable stair is the one the foot stops noticing. Each tread arrives where the stride already expected it; nothing in the flight asks the body to renegotiate the next step. Rise, going, pitch and headroom are only the geometry of that quiet stride.

Site measurements, or dimensions taken off the drawings, are enough. The number of risers is varied until the going fits the floor space without making the flight feel steep. Timber, steel or concrete: the arithmetic of the treads does not change.

A comfortable private stair: going around 250–300 mm (never under 220 mm), rise 150–200 mm (Approved Document K caps a private rise at 220 mm), 2R+G often 600–650 mm. Headroom 2.0 m on the pitch line, not a millimetre less if the surveyor is due.

slabopeningheadroomHL
L = total length of the staircase, H = total height to climb. Headroom is measured at the tightest point: just before the edge of the opening.

Staircase measurements

Lengths and number of steps

From the lower finished floor to the upper finished floor.

Floor footprint, from the nosing of the first step to that of the last.

Opening in the upper floor, measured from the nosing of the last step.

Measured from the lower floor, ahead of the opening.

An asterisk after a trade term points to a short definition in the glossary at the end.

Why 2R+G belongs in Approved Document K

An adult stride on the flat is about 630 mm. Climbing spends the rise* twice — lift, set down — and the going* once. François Blondel* wrote that down in the seventeenth century as two risers plus one tread. England kept the arithmetic and put a band around it. Approved Document K*, the guidance that sits behind Part K of the Building Regulations, asks for 2R+G between 550 and 700 mm on a private stair. Joiners aim at 600–650 mm, because that is where the flight feels like walking, not like a ladder and not like a shuffle.

It is not physics. It is a body. Below about 550 mm the rises are too tall for the goings: the flight feels steep, the thighs notice, the foot clips the nosing. Above 700 mm the going stretches, the stride breaks, the heel lands early. The formula does not decide how many risers a storey needs. It judges whether a given pair of numbers is fit to walk.

2R + G = 550–700 mm (AD K, private)  ·  comfort often 600–650 mm  ·  R ≤ 220 mm, G ≥ 220 mm

A 180 mm rise wants a going near 270–290 mm to sit in the middle of the band. A 200 mm rise wants something nearer 250 mm. Working the other way — from the plan length available, to the going, then to a rise that keeps 2R+G honest — lands on the same pair. That said, 630 mm is a comfort target, not a single legal number. A cellar stair at 720 mm of 2R+G can be used. It is no longer a private stair in the Approved Document sense.

Rise, going, pitch and headroom: the four numbers that make a stair

Rise is top of tread to top of tread. Not the thickness of the board. A 40 mm tread on a 180 mm riser remains a 180 mm rise if the next tread sits 180 mm higher. Mixing the two throws the whole flight out by a step the foot will not forget.

Going is the horizontal distance from nosing* to nosing. That is where the foot lands. American drawings often say run for the same dimension; the form on this page uses that word in the results table. The tread board can be deeper than the going if the nosing projects. The extra millimetres help on the way up. They do nothing for Blondel, and they do not help on the way down. Treating tread depth as going produces a stair that is steep on paper and shallow on site, or the reverse.

Pitch* is the angle of the pitch line*. For a private stair in England, 42° is the ceiling. Steeper than that, the flight is heading towards a ladder. Headroom* is measured plumb, from the pitch line up to the soffit or the trimmer at the well*. Two metres. Not “about two metres if one ducks”.

On a straight flight the pitch line sits down the middle. On a stair a metre or more wide, Approved Document K measures the going of tapered treads 270 mm in from each side — not at 500 mm from the inner string, which is the continental habit. Narrower than a metre, the centre line is enough. In practice the two conventions are close on an 800 mm flight and drift apart as the stair widens.

Straight flight, quarter-turn, spiral: always measured on the pitch line

A straight stair is total rise divided by the number of risers, total going divided by the same number. That is all this page does.

Once the stair turns, the same arithmetic holds — provided it is read on the pitch line, not on the inner string and not on the wall. A quarter-turn becomes a straight flight “unrolled” along that line. A half-turn likewise. A spiral makes the line a circle (a helix in space), and the going is an arc, measured 270 mm off the inner edge if the code is English.

This calculator sizes R and G. It does not draw winders. For a 90° corner, the quarter-turn staircase calculator places the newel, the number of tapered treads, the inner and outer goings. For a full circle, the spiral staircase page does the helix. Here the drawing stays a section: one flight, one storey height, one plan length.

The useful order of work is the straight flight first, even when the finished stair will turn. Get R and G walkable. Then fold the pitch line.

Winding a turn without breaking the stride

In a turn the going pinches at the newel and spreads at the outer string. Leave the treads as raw tapers and the going on the pitch line will not match the straight treads before and after. The foot has learned a rhythm. It catches the mismatch on day three, not day one.

Winding (balancing) shifts the ends of the treads, in the curved sector, so that the going stays constant along the pitch line. Each tread is rotated about the point where it crosses that line. The first two straight treads either side of the turn are often pulled into the same shift, to soften the change. Less than half the going at the tight edge, and the foot has nowhere to land. About 100 mm at the inner string is a heel. Less than that, a tray coming downstairs has no support.

A half-turn staircase is two such corners in succession, and the same discipline applies. A spiral is not wound: every tread is already an equal sector. There is nothing to catch up.

Headroom and the well: how a short opening becomes a surveyor's note

Headroom is the clear height above the pitch line, taken at the leading edge of the well — the tightest point, the one the diagram on this page marks with a blue arrow. Approved Document K wants 2.0 m. Come in under that and the trimmer meets the forehead, a wardrobe will not come up, and the surveyor writes it down.

headroom = (H × well length / L) − slab thickness

A well shorter than the total going eats headroom. That is not a finishing detail. That is the hole that is missing. The fix is to lengthen the well, or to push the first riser back — which lengthens L, eases the pitch, and moves the measuring point. The fix is not “everyone will duck”.

Slab thickness, storey height minus the ceiling height entered in the form, takes a bite from above. A 200 mm slab and a tight well is often the millimetre that drops the figure under 2.0 m. Better on the drawing than on the stepladder, the week the partitions go up. Even so, 2.0 m is the private-stair figure. A public stair, a means of escape, a loft conversion under a collar-tie, each has its own argument, and this page is not that argument.

Timber, concrete, steel, stone, glass: same geometry, different nosing

The pair R/G does not care what the stair is made of. The nosing, the slip, the weight and the upkeep do.

  • Timber — light, easy to machine, it moves with moisture. Hardwood treads (oak, ash) wear better than a bare softwood. A planted nosing, a non-slip insert. British Standards on timber stairs cover workmanship, not Blondel.
  • Concrete — inert, heavy, it wants a foundation and reinforcement. Left fair-faced, tiled, or finished with timber treads. The riser is often cast with the tread. The nosing wears.
  • Steel — thin, almost any shape. Slippery on its own. A checker plate, an open riser with a non-slip nosing, a timber tread on a metal string. This page gives the developed length of the stringer*, not the section size.
  • Stone — slow wear, weight, cost. Solid treads or a facing. Outside, frost matters as much as 2R+G.
  • Glass — laminated toughened, fingerprints, light. The rise and going do not change. The test certificate does.

Mixed construction is ordinary: steel strings and timber treads, concrete carcass with a stone finish. The stride stays the same number.

Cellar, garden, alternating-tread: when private-stair limits no longer apply

A private stair in a dwelling sits, roughly, between 25° and 42°, rises 150–220 mm, goings from 220 mm up. Leave that band and Blondel remains a judge, not a target.

A cellar or service stair can take taller rises, shorter goings, a handrail, and light. Pitch climbs towards 40–45°. Usable if the trip is occasional. Not tenable as the only way into a dwelling.

Outside: frost, water, moss. A non-slip nosing, a slight cross-fall to shed water, sometimes a longer going — people walk more slowly, often carrying something. There is no good reason for the rise to exceed 160–170 mm: outdoors there is no inner string to grab as naturally as indoors. To turn the pitch into a percentage, the slope calculator speaks the language of the path and the drive, not of the stringer.

An alternating-tread stair (space-saver) is too steep for 2R+G. Treads are staggered, or the going is a sliver, pitch 50–70°. Approved Document K allows it only as a secondary access to a loft or similar, with conditions. It is not sold as the main stair. The Building Regulations, for daily access to a dwelling, talk about a width and a pitch that an alternating-tread flight does not meet.

Worked example: a 2.80 m floor-to-floor rise

Storey height 2.80 m, finished floor to finished floor. A rise around 170 mm gives 2.80 / 0.17 ≈ 16.5. Take 17 risers. 2.80 / 17 = 165 mm. To sit 2R+G at 640 mm: G = 640 − 2 × 165 = 310 mm.

If the arrival landing counts as the floor, there are 17 risers and 16 goings “in the stair” — the sixteenth going is already the upper floor. This page divides L and H by the same n. So the count has to be stated. Enter 17 steps and a length of 17 × 310 mm = 5.27 m, and that is 17 goings including the landing. Enter 16 steps and L = 4.96 m, and that is the other convention: the last going is the upper floor, outside L.

The default on this form (16 steps, H = 280 cm, L = 480 cm) returns R = 175 mm, G = 300 mm, 2R+G = 650 mm, towards the top of the comfort band. Switch to 17 steps without changing L: R = 165 mm, G = 282 mm, 2R+G = 612 mm — fine on the sum, a little tight on the going. Stretch L to 527 cm for 17 steps and G comes back to 310 mm, 2R+G to 640 mm. The number of risers sets R; the plan length sets G; 2R+G judges the pair.

n ≈ round(H / 170 mm)  ·  R = H / n  ·  G = 640 mm − 2R  ·  L = n × G

Pitch: arctan(2.80 / 5.27) ≈ 28°. Ordinary dwelling. Headroom depends on the well. A 4.30 m well on a 5.27 m going, 200 mm slab, 2.60 m ceiling: headroom clears 2.0 m if the figures hold. A 3.50 m well, not so much. The form shows it before the stringer is cut.

Equal rises, or the removal-day trip

A first riser at 190 mm and the rest at 165 mm is the classic removal-day accident, the step everyone misses. The body learns the first, and repeats it. Five millimetres is felt. A centimetre is seen. The leftover millimetre is spread across every rise. It is not hidden under the first carpet, and it is not dumped into a little threshold at the top.

The same rule holds for going on the pitch line. 280 mm at the bottom, 320 in the middle, 290 at the top is a flight with no rhythm. Winding, in a turn, exists to stop exactly that scatter.

Nosing, total going, and the stringer

The nosing does not enter 2R+G. It enters comfort and wear. A 16 mm nosing, required in some cases where risers are open, does not lengthen L as this calculator measures it — L is nosing to nosing. It does change how much board the eye sees, and the chance of catching a toe if the nosing is too sharp or too slippery.

Total going on plan, excluding the last tread, is L − G. That is the footprint left at the bottom of the flight. The last tread already “belongs” to the upper floor.

The stringer is the raking member that carries the treads — a close string, a cut string, a pair, a central spine. Its true length, last tread omitted, is the hypotenuse × (n−1)/n. On a straight flight the handrail is often the same length. This page gives that dimension. It does not size the timber section or the steel channel.

Clear width, guarding and the handrail

800 mm clear width is a common private minimum. A metre once the public is in. The handrail around 900 mm above the nosings. A handsome stair that is too tight remains a funnel: the sofa for the first floor, a stretcher, two people passing.

Guarding is not decoration. Height, infill, no climbable rails, openings small enough that a 100 mm sphere will not pass. This page does not draw any of that. A correct rise and going with a low guard is a stair that will not pass. Widening the flight after the strings are in costs more than allowing for it: the well, the going, the newel, everything moves.

Glossary

Blondel's formula
The relation 2R + G, taken from an adult stride. François Blondel set it down in the seventeenth century. Approved Document K keeps it as a band (550–700 mm on a private stair), not as a single magic number.
Rise
Vertical distance from the top of one tread to the top of the next. Not the thickness of the tread board. Private stairs in England: 220 mm maximum.
Going
Horizontal distance from nosing to nosing. Where the foot lands. American drawings often say run. Distinct from tread depth, which includes any nosing projection. Private stairs: 220 mm minimum.
Pitch
Angle of the pitch line to the horizontal. Private stairs in England: 42° maximum. Steeper than that, the flight is leaving the dwelling-stair category.
Pitch line
The line of travel. Mid-flight on a straight stair. On tapered treads, 270 mm in from each side if the stair is a metre or more wide (Approved Document K); otherwise the centre line.
Headroom
Clear height, measured plumb from the pitch line to the soffit or trimmer. 2.0 m in Approved Document K. A short well is what reduces it.
Well (opening)
The hole in the upper floor that the stair rises through. Shorter than the total going, it cuts headroom at the tightest point — the leading edge of the opening.
Stringer (string)
The raking member that carries the treads: close string, cut string, or a central spine. Its length follows the hypotenuse of the flight, last tread omitted.
Nosing
The projection of the tread beyond the riser. It lengthens the board, not the going. Useful on the way up; ignored by 2R+G.
Approved Document K
The statutory guidance to Part K of the Building Regulations in England (protection from falling, collision and impact). It sets the private-stair limits on rise, going, 2R+G, pitch and headroom used on this page. Wales, Scotland and Northern Ireland publish their own documents.

Related calculators