EN

Beam Bending: Moment, Stress & Deflection

Bending is the workhorse loading of building and mechanical design: any part resting on supports and loaded across its axis — a joist, a lintel, a shelf, an axle — bends. Pick the type of bending in the tabs below: simply supported beam or cantilever, point or distributed load. The calculator returns the maximum bending moment, the support reactions, the deflection compared with the serviceability limit, and the stress if you know the section modulus.

Bending calls for two independent checks: strength (σ = M/W against the yield strength) and stiffness (the deflection against L/250 or similar). On ordinary spans, it is very often the deflection that governs, not the stress.

Type of bending and parameters

Simply supported beam, central point load — M = F·L / 4 ; f = F·L³ / (48·E·I).

fFL
Load and span
Section and material

From the section catalogue (Iy, strong axis) — 869 cm⁴: IPE 160. Rectangle: I = b·h³/12.

Optional (0 to skip): adds the stress σ = M/W. W = I / v. 109 cm³: IPE 160.

E and Re fill in automatically (except "Custom").

Used only when "Custom" is selected.

Used only when "Custom" is selected.

Simply supported beam, uniformly distributed load — M = q·L² / 8 ; f = 5·q·L⁴ / (384·E·I).

fqL
Load and span

Self-weight included: convert a mass per metre by multiplying by g ≈ 9.81.

Section and material

From the section catalogue (Iy, strong axis) — 869 cm⁴: IPE 160. Rectangle: I = b·h³/12.

Optional (0 to skip): adds the stress σ = M/W. W = I / v. 109 cm³: IPE 160.

E and Re fill in automatically (except "Custom").

Used only when "Custom" is selected.

Used only when "Custom" is selected.

Cantilever, point load at the free end — M = F·L ; f = F·L³ / (3·E·I).

fFL
Load and span
Section and material

From the section catalogue (Iy, strong axis) — 869 cm⁴: IPE 160. Rectangle: I = b·h³/12.

Optional (0 to skip): adds the stress σ = M/W. W = I / v. 109 cm³: IPE 160.

E and Re fill in automatically (except "Custom").

Used only when "Custom" is selected.

Used only when "Custom" is selected.

Cantilever, uniformly distributed load — M = q·L² / 2 ; f = q·L⁴ / (8·E·I).

fqL
Load and span

Self-weight included: convert a mass per metre by multiplying by g ≈ 9.81.

Section and material

From the section catalogue (Iy, strong axis) — 869 cm⁴: IPE 160. Rectangle: I = b·h³/12.

Optional (0 to skip): adds the stress σ = M/W. W = I / v. 109 cm³: IPE 160.

E and Re fill in automatically (except "Custom").

Used only when "Custom" is selected.

Used only when "Custom" is selected.

The glossary defines each asterisked term, once, where it first appears.

A bent beam is two stories at once

One face in compression, the opposite face in tension, and a neutral axis* in the middle that does no axial work. Peak fibre stress is σ = M v / I, the same relation as σ = M / W with the section modulus* W = I / v. The bending moment* M comes from the load and the supports — the four formulae in the tabs. W comes from the cross-section, not the material. I-beams park metal far from that axis: a larger second moment of area* I, a larger W, the same mass.

σ = M v / I  ·  σ = M / W  ·  W = I / v  ·  f depends on E and I, not on Re

Two checks, kept apart. Strength sets σ against the yield strength* Re. Stiffness sets the deflection* f against a fraction of the span (L/250 is the everyday floor).

On ordinary building spans it is very often the sag that governs, not the stress. A beam can sit nowhere near yield and still crack a partition, bounce a floor, or worry the eye. A higher steel grade will not fix a bouncy joist. Re does not sit in the deflection formula. Young’s modulus* E and I do.

Picking the right load case

  • Simply supported, central point load — the textbook case: a machine on a beam, an axle, a point load at mid-span. Worst place for a concentrated force.
  • Simply supported, uniform load — the building case: self-weight, a floor, snow. At equal total load (q L = F) the moment is half the central-point value.
  • Cantilever, end load — a balcony, a jib, a lifting arm. The moment grows linearly to the root, which takes everything.
  • Cantilever, uniform load — a canopy, a cornice. Everything is decided at the fix, with an L⁴ deflection that punishes extra length.

M = F L / 4  ·  f = F L³ / (48 E I)

M = q L² / 8  ·  f = 5 q L⁴ / (384 E I)

M = F L  ·  f = F L³ / (3 E I)

M = q L² / 2  ·  f = q L⁴ / (8 E I)

Equal span, equal load, the cantilever is in another league under a point load: four times the moment and sixteen times the deflection. A 1.5 m balcony wants as much attention as a 6 m beam. The sketch looks short. The arithmetic does not care.

Self-weight belongs in q: a steel IPE is not “weightless until the live load arrives”, and the line load to add is kg/m × 9.81. Timber is kinder on this point; a deep glulam on a long span is not.

Strength and stiffness are not the same lever

σ < Re means the extreme fibre has not yielded. f < L/250 (or L/150 on a cantilever, L/500 under a glazed screen) means the beam is stiff enough for the use.

Switching S235 to S355 changes the first check and leaves the second untouched. Same E, 210 GPa. Same I. Same sag.

Stiffness comes from a deeper section — I grows with h³ for a rectangle, and an IPE’s Iy jumps fast from one serial size to the next — or from a shorter L, because deflection runs with L³ or L⁴. A grade change is the wrong knob. A web stiffener is the wrong knob too, unless shear or local buckling is the real complaint.

A floor that feels right sits nearer L/300 to L/400 than the L/250 minimum. The extra millimetres of depth cost less than an argument about a bouncy room.

Worked examples

  • IPE 160 in S235, 4 m span, 3 kN/m — M = 6 kN·m, σ ≈ 55 MPa (s ≈ 4.3): lots of strength in hand. Deflection ≈ 5.5 mm = L/730. The section is chosen on stiffness, with margin to spare.
  • C24 timber joist 100 × 200 over 4 m — I = b h³ / 12 ≈ 6,667 cm⁴, W ≈ 667 cm³. Timber buys back its low E (11 GPa) with depth. The 200 mm dimension is the depth, not the width, or I collapses by a factor of four.
  • A shelf of books — 19 mm board, 80 cm span, a visible sag. Cutting the span to 60 cm drops the deflection about 58% (the L³ / I law). Same board, different furniture.

The 869 cm⁴ and 109 cm³ defaults on the form are that IPE 160. A starting point, not a size for every span.

Steel, aluminium and timber as beams

Deflection talks only to E and I. S235 and S355 sag alike; only the allowable σ moves. That is what makes timber distinctive: E roughly 19 times smaller than steel, so a joist needs the depth its low density can afford. Glued laminated GL24h keeps solid-wood stiffness and averages out knots, which allows a longer span than a single plank.

Aluminium (E ≈ 70 GPa, a third of steel) needs a taller section for the same sag. Sensible when mass beats bulk — a mobile gantry, an aircraft floor, a gangway.

Stainless 304 is almost steel in bending (E ≈ 193 GPa). The difference is rust, not stiffness, and Re is a little lower than S235.

A timber Re of 24 MPa in bending is a grade property along the grain, with load duration and moisture already in the background of Eurocode 5. Entering 24 MPa as if it were a steel yield, and applying a steel factor of 1.5, mixes two codes. The timber Re is a first filter; kmod and γM follow when the joist is a real floor.

Lateral-torsional buckling* of an I-beam

A slender I-section in bending can fail by rolling over: the compression flange buckles sideways and the section twists. Lateral-torsional buckling, LTB, is the bending cousin of Euler. This page does not compute it.

Unrestrained beams more than a few metres long, a roof purlin, a crane girder with no top-flange stay: LTB often governs long before σ = M/W reaches Re. What fights it is a fatter compression flange, a closed section (a rectangular hollow hardly buckles this way), full lateral restraint of the compression flange (deck welded or nailed to the top), or a shorter unbraced length. Eurocode 3 uses a reduction χLT on the moment. AISC uses a three-branch Mn against Lb, the unbraced length. Both sit well below the elastic M = σ W of this form when Lb is large.

A timber joist with a floor diaphragm nailed to its top is restrained. The same joist, used as a ridge beam with no sheathing, is not. Where the restraint cannot be named, LTB is in play, and σ = M/W alone is not a sufficient check.

The formulae assume a straight prismatic beam in linear elasticity, loaded in its plane of symmetry. They do not cover lateral-torsional buckling of slender I-sections, nor shear deformation in short stocky beams, nor the load combinations of a code (γ factors on dead and live). A real floor or a load-bearing frame needs that check.

Section modulus: the sister page

W is not a material property. It is I divided by the distance v from the neutral axis to the extreme fibre.

W = b h² / 6   (rectangle)  ·  W = π d³ / 32   (circle)

For an IPE, Wy is read from the table — 109 cm³ for the IPE 160 used as the default. A zero in the W field skips the stress; M and f are still returned. The section modulus calculator builds W from a shape, and returns the second moment of area I with it — needed for deflection even when σ is never requested. Both numbers feed this form: I for f, W for σ. Mixing them up (I in the W box, or cm⁴ in a cm³ field) produces a dimensionally meaningless stress and, on occasion, a plausible-looking MPa.

Elastic W is what σ = M/W uses. Plastic Wpl is larger — 1.5 times for a rectangle, about 1.12 to 1.15 for an I-section — and Eurocode 3 Class 1 and 2 sections are allowed to go there at ULS. This page stays elastic. Fine for a first size. Short of a plastic hinge check.

Shear in a short, stocky beam

Euler–Bernoulli bending, the theory behind the tabs, ignores shear deformation. Fair on a slender span (L greater than about 10 times the depth).

On a short deep beam — a lintel, a machine bed, a lifting lug that is really a deep cantilever — the shear stress in the web is no longer a footnote, and the extra deflection from shear can match the bending term. V is the shear force, equal to the support reaction on these four cases. For the simply supported point load, each reaction is F/2, so the web sees F/2. An IPE web is a thin strip; τ = V / (tw hw) can approach Re / √3 long before the flanges approach Re in bending.

τweb ≈ V / Aweb   (I-section)  ·  τmax = 1.5 V / A   (rectangle)

That is a shear check, and it belongs next to σ = M/W on any beam with L / h smaller than about 8.

Deep timber beams have the same issue along the grain, with a much lower allowable shear. A 200 mm joist on a 1 m span is a shear member that happens to resemble a beam. The web, or the grain, is sized before a tiny M is treated as the whole storey.

What the four formulae quietly assume

Constant section, linear elasticity, small rotations, load in the plane of the web, supports that match the tab (simple, or a true fix). A beam that changes depth, a haunch, a hole in the web, a load hanging off one flange: none of that is in M = F L / 4.

A “fixed” end that is a pair of bolts in a thin plate is a spring. The moment at the root is less than F L, and the sag is more than F L³ / (3 E I).

Load combinations are another silence. Eurocode uses γG ≈ 1.35 on permanent and γQ ≈ 1.5 on imposed for the strength check, and almost unfactored loads for the sag check. AISC LRFD has its own pair. This form takes the entered load a single time. Comparing σ with Re / 1.5 after a working load is entered is an allowable-stress sketch, honest when it is labelled as such. Entering a factored ULS load and dividing by 1.5 counts the margin twice.

A shaft that bends and twists needs σ from this page and τ from the torsion calculator, superposed, and a von Mises equivalent. A rotating axle with a pulley is that combination. Neither page alone is the answer.

Glossary

Neutral axis
The fibre that does no axial work in bending: tension on one face, compression on the other.
Section modulus
W = I / v, with v the distance from the neutral axis to the extreme fibre. σ = M / W is the same as σ = M v / I. A property of the shape, not of the material.
Bending moment
M, set by the loads and the supports. The four peaks are F L / 4, q L² / 8, F L and q L² / 2.
Second moment of area
I, fixed by the cross-section alone. Deflection formulae use E I, and W is I / v.
Yield strength
Re, the stress at which the extreme fibre yields. s = Re / σ. A higher Re leaves the deflection unchanged.
Deflection
f, the transverse displacement. It depends on E, I and the span, not on Re. An ordinary floor is often checked at L/250.
Young’s modulus
E, the elastic stiffness of the material: 210 GPa for S235 and S355. Present in every deflection formula, absent from σ = M / W.
Lateral-torsional buckling
The compression flange moving sideways as the section twists. Not calculated here. On a long unrestrained I-beam it can govern before σ = M / W reaches Re.