Pump Power Calculator (TDH & Motor Sizing)

A pump turns a motor's mechanical power into hydraulic energy: it moves a fluid and raises its pressure. Its useful power depends on the flow it delivers and the head it must overcome — the total dynamic head (TDH), which combines the geometric height and the circuit's head losses. Since no pump is perfect, the power actually absorbed on the shaft always exceeds the useful hydraulic power, by the efficiency ratio.

Enter the flow rate and the head to overcome (as height or as pressure), pick the fluid and the pump's overall efficiency: the calculator gives the useful hydraulic power, the power to plan for on the shaft, and the next standard motor rating above it. Note this is a MOTOR driving a PUMP to move fluid — the reverse of a hydroelectric plant, where falling water drives a turbine to generate electricity.

reservoirMpumpQH

Flow rate, head and efficiency

Flow rate and head to overcome

Change the mode then "Calculate" to show the matching field.

Geometric height + circuit head losses.

Fluid and efficiency

ρ auto-fills (except "Custom").

60 to 75 % for a typical centrifugal pump, higher for a positive-displacement pump.

Pump terms followed by an asterisk are defined in the glossary.

Total dynamic head: geometric height, head losses, service pressure

Building height is not pump head. Total dynamic head* — HMT on a French data sheet — is the energy given to each newton of fluid, in metres of that fluid. A metre of water and a metre of oil are the same head and different pressures.

Three parts go into the sum. None replaces another.

Static, or geometric, head is the vertical lift from the free surface to the discharge point. Pipe head loss is added on top: wall friction, elbows, valves, strainers, growing roughly with Q². Service pressure is what the nozzle, cylinder or vessel requires at the far end, turned into metres. Omitting any one part leaves the pump matching the paper duty, and short of head once the line is full.

H = Hgeo + Δhloss + Δpservice / (ρ · g)

Ph = ρ · g · Q · H  ·  Ph = Q · Δp  ·  Δp = ρ · g · H

Head form and pressure form meet in that last equality, the same link as hydrostatic pressure. The data sheet may use either writing of the hydraulic power*. Shaft power does not switch: Pa = Ph / η.

Centrifugal vs. positive-displacement pumps: the head-flow curve and duty point

A centrifugal pump is a turbomachine. The impeller throws the liquid and produces the head.

The H(Q) curve falls as flow rises. Opening the discharge passes more liquid and the head drops away. The duty point* is not a nameplate setting. It is where the pump curve crosses the system curve — static lift, plus losses that rise with flow.

A positive-displacement pump — piston, gear or vane — traps a volume and drives it out.

At a fixed speed the flow barely moves when the pressure changes, up to the point where the relief valve lifts. Excavators, presses and injection moulders are built around that behaviour, at 250 to 350 bar and sometimes 700 bar. Water transfer, crude and tank-to-tank duty stay with centrifugals in nearly every case.

The families are read in opposite directions: flow to head on a centrifugal, speed and displacement to Q on a positive-displacement machine, with the load fixing Δp. Bought on the wrong family, the brochure can show the flow while the skid misses the priced duty.

Available vs. required NPSH: the risk of suction-side cavitation

When absolute pressure at the impeller eye falls below the liquid's vapour pressure, the liquid boils there. Bubbles grow, then collapse as soon as pressure recovers inside the pump. Each collapse pits the metal.

The volute sounds full of gravel, and flow and efficiency both fall. An impeller can be eaten through in a few months, sometimes in a single shift.

NPSHr* is the maker's figure: the head the pump needs, at the stated flow, to stay off cavitation*. NPSHa is calculated for the suction pipework as built. NPSHa has to exceed NPSHr.

The margin quoted in specifications runs from half a metre to a metre, or as a ratio from 1.1 to 1.3. With no margin, the first dirty strainer is enough to start the damage.

NPSHa = (patm − pv) / (ρ · g) + zs − Δhsuction

zs is positive on a flooded suction, free surface above the eye, and negative on a suction lift. Suction loss Δhsuction — a long hose, an undersized suction main, a clogged foot valve — comes straight off NPSHa, and a larger motor does not put that head back. Hot water is harder, vapour pressure being higher; cold borehole water is easier. NPSH belongs to the suction pipe, not to the kilowatt rating.

A cavitating pump can keep passing flow for a time. Gravel noise, vibration and a falling efficiency are the signs; a shorter suction, a flooded layout or a lower duty costs less than a new impeller.

Hydraulic, volumetric and mechanical efficiency: where the total loss comes from

The η entered here is an overall efficiency*. Three losses of different origin sit inside it.

Hydraulic efficiency ηh accounts for fluid friction in the impeller, shock at the vane inlets and eddies in the passages. Volumetric efficiency ηv accounts for internal slip: clearance between piston and bore, recirculation across a gear mesh, a worn wear plate. Mechanical efficiency ηm accounts for bearings, seals and packing.

η = ηh · ηv · ηm  ·  Pa = Ph / η

On a water centrifugal, ηh is usually the largest part of the loss, particularly away from the BEP*. On a high-pressure positive-displacement pump, ηv dominates: slip rises with Δp, and hot thin oil pushes it the same way. An axial-piston unit in good order might run at ηh ≈ 0.92, ηv ≈ 0.95 and ηm ≈ 0.95, about 83% overall. A small sump centrifugal is already a good machine at 60 to 75%.

The efficiency to use is the value at the duty, not the catalogue peak. That peak is BEP. Ten percent of flow to either side, η has already fallen and shaft power Ph / η rises.

Variable-speed drives and affinity laws (flow, head and power vs. speed N)

On a centrifugal, a lower speed is not a light trim. At fixed impeller diameter the affinity laws* apply.

Q ∝ N  ·  H ∝ N²  ·  P ∝ N³

A cut of 20% means running at 80% of nameplate speed. Flow moves with speed, down 20%. Head falls by 36%, 0.80² being 0.64. Absorbed power falls by nearly 49%, 0.80³ being 0.512.

That N³ relation is why a variable-speed drive on a circulating or irrigation pump often pays for itself in a couple of seasons: a throttle wastes the difference in the valve, and the drive does not supply it.

On a 40 m rising main with little friction, a lower N walks the pump off the useful curve. Available head shrinks, and flow dies faster than the simple proportion. The affinity laws compare homologous points on the pump curves, not an arbitrary point on the network.

On a positive-displacement pump, flow follows N and displacement. Pressure comes from the load, not from N², and at constant Δp power follows N rather than N³. A drive cuts kilowatts when full flow is not required; below the maker's minimum speed, lubrication and mechanical efficiency fall off.

Pumps in series and in parallel: stacking head or flow rate

One machine is not always enough. Two will, if they add the quantity the duty is short of.

  • Series — discharge of the first into the suction of the second. One stream, flow in common. Heads add. Typical duties are a two-stage booster, or a sump pump feeding a high-lift unit.
  • Parallel — two suctions in the same wet well, two discharges into one manifold. Head is shared and does not add. Flows add. The usual arrangement is duty-standby, with the second machine brought on to lop the peak.

Dissimilar curves cause the trouble. In parallel the weaker head curve can sit at zero flow, or reverse if the non-return fails. In series the second stage may see an inlet pressure its casing is not rated for.

Similar pumps, a check valve on each discharge, and an NPSH check on every machine are the minimum. The first stage of a series set is the one that cavitates.

Annual running cost of a pump at its actual duty point

The purchase is a small slice of the lifetime cost; after commissioning the spend is shaft power times hours times the price of a kilowatt-hour. An 11 kW centrifugal at 6,000 h/year and 16 p/kWh already spends a bit over £10,000. Each efficiency point lost shows in that figure once the year is closed.

Cyear ≈ Pa (kW) × t (h) × ckWh

The first lever is the duty relative to BEP. Off the peak, η drops and Pa rises for the same hydraulic output, while the bearings see recirculation, high radial load and noise. The second lever is head the process does not require: a pipe that is too small, a valve left half shut, a strainer forgotten in the line. The third is a variable-speed drive, when full flow is not wanted for the whole run.

Tariff and hours have to be the real ones.

A storm-water sump may run 200 h a year. A process pump may run 8,000 h. A neat 2,000 h, taken from an office working year, fits neither machine.

Worked example: a sump pump, a hydraulic circuit pump on heavy equipment

Sewage sump, centrifugal. 50 m³/h against 45 m of head, water at 1,000 kg/m³. Q = 50 / 3,600 = 0.0139 m³/s.

Ph = 1,000 × 9.81 × 0.0139 × 45 ≈ 6.13 kW

At 78% efficiency, Pa = 6.13 / 0.78 ≈ 7.9 kW. The IEC series has no 7.9 kW rating. The next standard motor is 11 kW, and the step looks wide until starting current, rag on the strainer and a possible altitude derate are included. NPSHa is a separate sum, on the suction main alone.

Machine hydraulics, positive-displacement. Axial-piston, 60 cm³/rev, 1,800 rpm, 250 bar, η = 88%.

Theoretical flow is Q = V · N. With V = 60 × 10−6 m³/rev and N = 30 rev/s, Q = 0.0018 m³/s, or 108 L/min. Displacement fixes the flow; the load fixes the pressure.

Ph = 0.0018 × 250 × 105 = 45 kW  ·  Pa = 45 / 0.88 ≈ 51 kW

The IEC motor is 55 kW. Two thousand hours a year at that duty, at 15 p/kWh, is about £15,300 — cutting N when the ram does not need full flow, or moving to variable displacement, is diesel burned, not a note left on the drawing.

IEC frames versus NEMA horsepower

Selection steps up to the next IEC kilowatt: 0.75, 1.1, 1.5, 2.2, 3, 4, 5.5, 7.5, 11, 15 and so on (IEC 60072). No 8.4 kW frame exists. The next rating is 11 kW, and that spare covers across-the-line starting and a fouled suction.

A NEMA nameplate makes the same step in horsepower (1 hp ≈ 0.746 kW), often with a service factor of 1.15. The two series are not interchangeable, and rounding down from one list onto the other is not a selection.

An oversized motor is not a free reserve: at light load, efficiency and power factor are poor, and the starter costs more. A centrifugal starting against a closed discharge already draws 6 to 8 In; a soft starter or a variable-speed drive holds that inrush inside the breaker rating. A positive-displacement pump starts with the load dumped to tank, and must not see 250 bar on the first revolution.

Flooded suction, suction lift and priming

A centrifugal does not draw liquid up a dry suction pipe. With the free surface below the eye the arrangement is a suction lift, and the casing has to be primed: a foot valve, a primer, or a self-priming body with a recirculation well.

Each metre of lift is a metre off NPSHa. Each metre of suction loss is another. Flooded suction — the set in a wet well, or a tank whose free surface sits above the centreline — does not depend on a primer staying tight.

Self-priming centrifugals cost head and efficiency, and the suction has to stay airtight. A positive-displacement pump often primes itself and can pull a deeper lift. Cavitation follows if NPSHa lies below NPSHr. Care belongs on the suction run; the discharge can be awkward.

Off-BEP running: vibration, bearings and recirculation

BEP is the cheap place to run, and the mechanically easy one.

Far to the left of it — low flow, high head — the impeller recirculates, radial load on the shaft rises and seals start to weep. Far to the right, NPSH runs out. The pump cavitates, and the shaft draws more power than the motor was bought to supply. A throttle put in to trim a centrifugal that is much too large holds the duty in that low-flow region for the life of the installation.

A moving duty sits better on a variable-speed drive, or on a parallel pair with one machine stopped — a building whose demand halves at night, a quarry that only sometimes needs the second monitor. Bearings and the electricity account register that mismatch on different timescales.

Glossary: hydraulic power, overall efficiency, NPSH, BEP, head

Hydraulic power
Useful power in the fluid, Ph = Q · Δp or Ph = ρ · g · Q · H. Shaft power is that quantity divided by overall efficiency.
Overall efficiency
η = Ph / Pa, the product of hydraulic, volumetric and mechanical efficiency.
NPSH
Net positive suction head. NPSHr is what the pump needs at a given flow; NPSHa is what the suction provides, and NPSHa has to be the larger figure.
BEP
Best efficiency point, the flow of highest efficiency. Low flow raises radial load, high flow raises NPSH demand, and shaft power rises on both sides.
Head
Energy per unit weight, written as a height of the fluid. Total dynamic head adds geometric lift, pipe loss and service pressure in metres.
Duty point
Flow and head at the crossing of the pump curve and the system curve.
Cavitation
Boiling at vapour pressure, followed by bubble collapse: pitting, a gravel-like noise and lost efficiency.
Affinity laws
On a centrifugal at fixed impeller diameter, flow scales with speed, head with speed squared and power with speed cubed, and only between homologous points.

Related calculators