Motor Power, Torque and Speed Calculator

Four basic conversions come up constantly in electrical engineering, whatever the motor type (induction, synchronous, DC): going from torque and speed to mechanical power, working out the electrical power drawn from the supply, checking an efficiency figure, or finding a motor's synchronous speed from the supply frequency. This page brings all four together in one quick tool.

For the full calculation of a specific three-phase induction motor — slip, useful torque and current from its nameplate — see the dedicated calculator, which goes into more detail for that specific case.

The four calculations

A. Mechanical power (from torque and speed)
B. Absorbed electrical power
  
C. Efficiency
D. Synchronous speed

The number of poles (2, 4, 6…), not the number of pole pairs.

Results

  • A. Mechanical power 7.59 kW
  • B. Absorbed power 17.48 kW
  • C. Efficiency 93.2 %
  • D. Synchronous speed 1,500 rpm

The four formulas

A. P = C × N ÷ 9,550 (P in kW, C in N·m, N in rpm)

B. Three-phase: P = √3 × U × I × cos φ ÷ 1,000 · Single-phase: P = U × I × cos φ ÷ 1,000

C. η = Poutput ÷ Pinput

D. Ns = 120 × f ÷ p

Active, reactive and apparent power: what a power factor actually measures

Block B asks for a power factor. That number is not a fudge factor. On AC, voltage and current are not always in step. The product U × I is apparent power S, in VA. Only the in-phase slice does work: that is active power P, in watts. The rest sloshes in and out of magnetic fields — reactive power Q, in var. Power factor is the cosine of that phase angle, P/S.

P = S · cos φ · Q = S · sin φ · S² = P² + Q²

A motor at full load might sit at 0.85 to 0.90. At no-load the current is mostly magnetising, so cos φ collapses even though the motor is “doing nothing”. Three-phase input power therefore needs the √3, the line-to-line voltage, the line current and that cosine. Leave cos φ at 1 and you have sized the kW as if the motor were a heater. It is not.

The cables and the breaker care about S, not P. A poor power factor means more amps for the same shaft work — thicker cables, more I²R in the plant, and sometimes a kvar charge on the bill. That is a three-phase power story, not a motor-efficiency story, but it is why the field is there.

Rated torque vs useful torque vs starting torque: the difference

Block A gives you a torque and a speed and hands back mechanical power. Which torque did you type?

  • Rated (full-load) torque — the shaft torque at rated power and rated speed. The nameplate number. Continuous, thermal limit respected.
  • Useful torque — whatever the load is asking for right now. Could be half of rated, could be a bit over for a short while. Formula A does not care: C × N / 9,550 is instantaneous mechanical power, not a thermal rating.
  • Starting torque — torque at standstill. For an induction motor, often 1.5 to 2.5 times rated on a direct-on-line start, and a third of that in star-delta starting. Speed is zero, so mechanical power is zero even if the torque is huge. Do not feed a starting torque into block A and expect a meaningful kW.

Breakdown (pull-out) torque is another animal again: the peak of the torque-speed curve, typically twice rated or more. Useful for a stall check, useless as a running-power input.

Iron losses, copper losses, mechanical losses: where the lost energy goes in a motor

Efficiency in block C is just Pout / Pin. The missing slice is heat. It splits in a fairly honest way:

  • Copper losses — I²R in the stator winding, and in the rotor cage if there is one. They grow with load. At full load they are often the biggest single term.
  • Iron losses — hysteresis and eddy currents in the laminations. They depend on flux and frequency, so they stay roughly constant if the V/f ratio is held. At light load they dominate the loss pie.
  • Mechanical losses — bearings, fan, windage. Also fairly flat with load, rising with speed.
  • Stray load losses — the leftovers: harmonics, leakage, a bit of everything the other three did not catch.

A 15 kW motor at 93 % efficiency dumps about 1.1 kW as heat. That heat has to leave the frame. Oversizing “to be safe” and then running at 30 % load is how you pay iron and fan losses all day for shaft work you are not doing.

Part-load efficiency: why it isn't constant across the whole power range

The peak of the efficiency curve is usually around 75–100 % of rated load. Drop to 25 % and the iron and windage are still there, so η falls. A nameplate of 93 % can be 88 % at quarter load without anyone having lied. Block C will faithfully report whatever two powers you give it. It will not warn you that last week's full-load test is the wrong number for today's dampered fan.

PM synchronous motors hold their efficiency further down the curve — less rotor copper, less magnetising current. Induction motors less so. If you are comparing the two, a single nameplate η in each column is an approximation, not a map.

Converting torque in N·m from power in horsepower

Datasheets still quote horsepower. Mechanical power in the SI formula wants kilowatts. One mechanical horsepower is 745.7 W; the round 746 is what everyone uses. Metric horsepower (PS, ch) is 735.5 W — a different animal, still printed on some European plates. Check which one you have before you invert the torque formula.

PkW = hp × 0.746 · C = 9,550 × PkW / N

A 20 hp motor at 1,770 rpm: P ≈ 14.9 kW, C ≈ 80.5 N·m. Same shaft, same formula as block A, just a unit stop on the way in. In fact the 9,550 is itself a unit converter — more on that below.

Synchronous speed and slip: the link to the induction motor calculator

Block D is Ns = 120 × f / p. That is the speed of the rotating field, not the shaft. A four-pole motor on 50 Hz is 1,500 rpm synchronous. The shaft of an induction motor runs a little slower: that difference is slip. A typical full-load speed of 1,450 rpm is 3.3 % slip. A PM synchronous motor has none — shaft and field lock together.

s = (Ns − N) / Ns · Ns = 120 · f / p

p is the number of poles, not pole pairs. Two poles, 3,000 rpm at 50 Hz. Four poles, 1,500. Six, 1,000. Put pole pairs in that formula and you double the speed you expected — the classic nameplate misread. For slip, torque and line current from a full nameplate, the induction motor calculator is the page that actually uses all of this together.

Where the 9,550 comes from

Power is torque times angular speed: P = C × Ω, with Ω in rad/s. Rpm to rad/s is 2π/60. So Pwatts = C × N × 2π / 60. Divide by 1,000 for kilowatts and you get PkW = C × N / 9,549.3… Round it to 9,550 and nobody on a shop floor will notice. Use 9,549 if you like; the torque transducer is not that good.

Forget the 9,550, multiply C in N·m by N in rpm, and you have a number in some private unit that is not watts. The constant is not optional.

Poles, frequency, and a 60 Hz supply

The same four-pole motor on 60 Hz is 1,800 rpm synchronous, not 1,500. A dual-frequency nameplate (50/60 Hz) usually lists both speeds and both currents. Voltage may change too: a 400 V 50 Hz winding is not automatically happy on 480 V 60 Hz without checking the V/f ratio. Block D only does the speed. It will not warn you about the flux.

What this page does not know

Four independent sums. They do not check each other. You can type a torque that would melt the motor, a power factor of 1 on a lightly loaded induction machine, or an efficiency above 100 % if you swap input and output. The arithmetic will still run.

Service factor, duty type (S1–S9), ambient derating and altitude are outside these four formulas. A motor rated 15 kW S1 at 40 °C is not a 15 kW motor in a 50 °C plant room. Size the thermal limit from the datasheet, not from block A.