EN

Calculate a Half-Turn Staircase: Landing or Winders

A half-turn staircase makes a full 180° turn between the lower and upper floor: the two flights come back parallel, side by side — either joined by a rectangular landing, or by winders that pivot around a newel post over a full half-circle. Pick a layout in the tabs below: the rise stays the same throughout, but the run is worked out differently on either side of the turn.

Unlike a 90° turn, the two flights of a half-turn stair naturally line up side by side: the total width depends directly on the tread width (and any gap between the two flights), not on their length.

Staircase dimensions

Two parallel flights joined by a rectangular landing. The rise is shared across both flights; the run is worked out separately on each one.

landingupL1L2
L1 and L2 are the run of each flight. The landing joins the two flights at the bottom; its depth is independent of their width.
Lengths, steps and unit

From the finished lower floor to the finished upper floor.

Distance between the two flights (0 if they sit back to back).

In the direction of travel, independent of the tread width.

Opening in the upper floor, measured from the nosing of the last step.

The turn is treated as a half-circle (180°) centred on the newel post. The walking line is fixed 0.50 m from the inner string; each winder occupies an equal angle.

newel + 7 winders
The newel post (black dot) is the pivot of the turn. The winders fan out over the whole southern half-circle, between the two flights.
Rise, turn and unit

Half the diameter of the centre post (or the inner string). Often wider than a quarter-turn's for a comfortable half-turn.

7 is the usual compromise for a 180° turn.

0 if the turn starts on the very first step.

Trade words marked with an asterisk are spelled out in the glossary at the end of the page.

Dog-leg, open well, half-landing: three shop names for a 180° return

British joiners keep two names for the same 180° return. A dog-leg has no well* at all: the inner strings* run back to back, and the upper rail ramps down to meet the lower one at a half-landing*. An open-well stair leaves a real gap between the flights — stand on the top floor and the eye drops straight down it. Same U. Same parallel flights. The gap field is the whole difference.

A quarter-turn bends 90°. The flights sit at right angles, and the plan spreads on two axes. A spiral has no straight flight left: every tread is a sector around one newel*, through a full turn or more. The half-turn sits between those two, and it is not an average. The tangent to the circle, at 0° and at 180°, is the same line. The inner strings face each other. Stacking two quarter-turns does not produce that. The first corner squares the flights; the second squares them again; the plan comes out as a Z, or as a lopsided U whose flights are no longer parallel.

Going* on the walking line*, a single rise, 2R+G* in the 550–700 mm band of Approved Document K — that judgement is the same as on a straight stair. The stair dimensions calculator works that pair. What belongs to the U is the footprint. Width first. Depth second.

Why the well width, not the going, sets the plan

A straight flight grows long. An L opens the hall both ways. A U folds back on itself. L1 and L2 run the same way, side by side, one up, one down. What opens the stairwell, then, is no longer the going on plan. It is twice the flight width, plus the well.

plan width = 2 × width + well  ·  plan depth = max(L1, L2) + landing depth

A 1.90 m stairwell will not take two 1.00 m flights, well or no well. It will take 900 + 0 + 900, just. Adding 400 mm to L1 does nothing to the width. It shoves the landing, or the trimmer, the other way. Bumping the flight from 800 to 900 mm, though, eats 200 mm of well at once. That is the lever a straight-stair habit misses: a single flight is sized by length, and the U is assumed to behave the same.

In depth, the longer of the two goings commands, plus the landing — or plus the outer radius, if the turn is wound. A shorter upper flight does not shrink the well. It leaves a wider arrival, or a half-landing shifted along the run. The figure that counts is the max.

Half-landing versus a 180° winder fan

A half-landing is not the square from the quarter-turn page. It is a rectangle. The body actually turns about, sets a box down, and takes the other flight. Both strings stay straight. 2R+G reads clean, tread after tread. The cost is depth: going plus landing, easily 3.50 m for a 2.80 m storey.

Winders* over 180° spend that depth. The turn is treads, a semicircle on the newel. L1 and L2, derived from the 500 mm going, shrink. Width on plan balloons: 2 × (newel radius + flight width). A skinny newel pinches the inner edge. A short, fairly wide well favours winders. A long, narrow well — a lot of Victorian terraces, a lot of 1950s blocks — takes the landing and refuses the semicircle.

A landing 1.10 m deep and 1.80 m wide is a real rest. Six 45° kites at the post is not a rest. It is a turn the foot has to learn, with nowhere to stop. The choice is not only millimetres on the floor. It is a choice of cadence.

The well between the two flights

The well is the slit. Zero, the inner strings kiss, or a partition sits between them. The hall disappears from view. A child does not go through. The stairwell is a block, opaque, compact. A hundred, two hundred millimetres, and the eye drops, and the light, from the roof lantern down to the mat. Too wide, and it is no longer a slit: it is a shaft, guarding on both inner sides, a well that has eaten the house.

On the landing tab the well is an input. It is typed. On winders it is an output: twice the newel radius. A 150 mm-radius core opens 300 mm between flights. An 80 mm tube, 160 mm, almost nothing. The newel is fattened for the inner going, not for the view. The two move together. A generous well and a pencil post is not this geometry.

Still, a closed well is not a fault. In a tight stairwell it is often the only way to keep 900 mm of clear width on each side. The quote gets simpler: one outer rail, no shaft to light, no net. An open well photographs better. It is another line on the invoice.

Four to twelve winders, and what the count does to the going

Four is 45° a tread, the floor of this form. Going opens, even at the newel. The outer edge spreads, often past 450 mm. Twelve is 15° a tread. Walking-line 2R+G behaves. The heel at the pole has nowhere. Seven, the form's default, about 26° — middle of the band.

“More winders, more comfort” is wrong at the tight edge. One hundred and eighty degrees are fixed. More slices, thinner slices. A 150 mm newel and 7 winders: inner going 67 mm. At 4 winders it climbs toward 120 mm, and the outer goes past 500. The pinch lever is newel radius. The outer-too-long lever is the count, or a narrower flight.

going(r) = π r / winders  ·  walking line: r = newel + 0.50 m

A 260 mm newel, 8 winders, 800 mm flight: 102 mm at the post, 298 mm on the walk, 416 mm at the wall. Liveable. An 80 mm tube and 7 treads “because the quarter-turn did it in three”: no. A half is not two quarters glued down. The angle to share is double; the inner edge melts twice as fast if the newel stays the one from the L.

How deep a half-landing has to be

On a quarter-turn the landing is a square of the flight width. 800 mm flight, 800 × 800 landing. On a half, that square is not enough. The body is not bending 90° round a corner. It is turning about. Depth is needed in the direction of travel, independent of flight width — hence the separate field, 1.10 m by default.

In a private house, at least the flight width, often more. 900 mm flight, landing 1.00 to 1.20 m deep, 1.80 m wide if the well is closed. Public, accessible, Part M — different drawing: a 1.20 m circle, sometimes 1.50, and a rail that does not steal it. This page sizes a house U. Not a protected shaft, and not a fire-fighting landing.

A 700 mm-deep landing is not a half-turn. It is a quarter landing parked in the wrong place. The stride breaks, and the corner newel becomes something to walk into.

In practice, 1.10 m is not a luxury. It is room to plant both feet, pivot, and take the upper flight without the first nosing catching a shin. Dropping under the flight width is already a concession. Dropping under 800 mm, and it is no longer a landing.

A handrail that does not let go through 180°

The hand does not let go, twice as long as at 90°. The inner rail follows a semicircle round the well, or two corner newels and a landing rail. The outer rail does the big U: further to travel, gentler pitch. Cut them from the same stick and twist them round, and the knuckle finds the landing post.

At the landing the rail may break if the landing guarding picks up — provided the palm finds the next stick without hunting, right as the body pivots. On winders the inner rail is a real semicircle, same newel as the treads, smaller radius than the walk. The outer is not parallel in section. Two bars, two cuts, two pitches.

Height, about 900 mm above the nosing. Inner side first, because that is where the hand holds in a tight U. Both sides once the well opens, or once the stair is used by strangers. A 300 mm well with no balusters is a hole. Approved Document K's 100 mm sphere applies to the slit between flights as well, not only to the outer guarding.

Tight stairwell: three sets of numbers

Well 1.90 × 3.60 m, storey height 2.80 m. Sixteen risers at 175 mm. 2R+G wants a going near 300 mm. Tight on width, honest on depth. A 1950s block, or a terrace between party walls.

  • With a half-landing. Two 900 mm flights, well closed, 8 + 8 treads, 2.40 m goings, landing 1.10 m. Going 300 mm, 2R+G 650 mm. Footprint 1.80 × 3.50 m. It fits, 100 mm to spare on each axis. The landing sits 1.40 m up.
  • Winders in the same well. 800 mm flight, 260 mm newel, 8 winders: width on plan 2.12 m. It spills. The semicircle is greedier on width than a closed-gap landing.
  • Winders that fit. 700 mm flight, 230 mm newel, 7 winders, 5 straight + 7 + 4 straight. Inner going 103 mm, walking line 328 mm, outer 417 mm. Footprint 1.86 × 2.57 m. A metre of depth back, 40 mm of width left, tight edge sitting on the 100 mm line.

R = 2.80 m / 16 = 175 mm  ·  going(r) = π r / winders

A long, narrow well wants the landing. A squarer well wants the winders. Both axes have to be read before the tab is picked. One axis taken off the plan, and the wrong geometry is drawn.

A landing too short to turn on

The usual: take the quarter-turn square, 900 × 900, park it at the end of two flights, call it a half-turn. The width is there (1.80 m). The depth is not. The foot arrives, gets one landing going, and hits the upper flight. Third removal day, it is always the same first riser that catches the box.

The twin, on winders: size the straight flights “as a straight stair”, 280 mm going, then cram six kites into the leftover semicircle. On the walking line the turn comes out at 220 mm, or jumps to 360. This page will not split it that way. It finds the 500 mm going first, then derives L1, L2 and the well. A typed going that would force a different cadence is not an input, on the winder tab.

A third, because it keeps coming back: a rise that changes after the landing. Eight at 170 mm, landing, eight at 190 because “there was height left”. One rise, the whole U. A landing is not a tread. It does not add a going. It does not forgive a taller riser afterwards. The body learned the first. It repeats it. Five millimetres is felt. A centimetre is seen.

Two quarter-turns in a row are not this U

It turns up on drawings that were done too fast. A quarter at the bottom, a quarter at the top, the rises added, and the sketch is labelled half-turn. Geometrically, no. Each quarter bends 90°. Two bends make a Z, or a U whose flights are no longer parallel if the newels are not lined up. The well, the plan width, the rectangular landing — none of that falls out of a quarter-turn copied twice.

That is why this page exists. The quarter next door, the spiral above. Three tools, three footprints. Copying the rises from a quarter-turn and “flipping” the sketch does not give the L1 and L2 of a U, nor the well, nor the landing depth.

Headroom lives on the upper flight

The landing tab works the headroom* under the upper opening, same idea as a straight stair: nosing to soffit, often 2.0 m, rarely under 2.0 m in a new dwelling (Approved Document K). The hole is a U, or two rectangles side by side. A single oblong “as if it were straight” leaves the lower string in the floor, or opens the sitting room for nothing. Follow both flights. Leave the landing under the slab if it sits low enough. Check the nosing of flight 2.

On winders, headroom is judged on the walking line of the semicircle and at the start of the upper flight. At the newel the head is elsewhere. It is the outer string that meets the trimmer. Move the first riser of flight 2, grow the U. Not “we'll duck”.

Slab thickness eats headroom from above, as everywhere. A 200 mm floor and a tight opening is often the millimetre that drops the clear height under 2.0 m. Better on the drawing than on the stepladder, the day the partitions go in.

Guarding the well, or closing it

A 200 mm well, a child's head. A 400 mm well, a leg. The 100 mm sphere between balusters applies to the slit between flights as well. Closed well, or guarded well. Not a “we'll see once it's in” in-between.

In practice a zero well simplifies the quote: one outer rail, no shaft, compact stairwell. An open well wants two inner rails, light, sometimes a net. Even so, an 80 mm slit “to let the light through” with no balusters lights almost nothing and stays climbable. Either open it properly — 300 mm and more, guarded — or close it.

A house U holds in a tight well if the gap is closed and the half-landing is deep enough. It holds in a squarer well if the winders sit on a decent newel. Both at once, in 1.90 × 3.60 m, does not fit.

Glossary

Well
The void between the two parallel flights. Closed (a dog-leg): the inner strings meet. Open: a light shaft — and guarding on both inner sides. On the winder tab, the well equals twice the newel radius.
Half-landing
The rectangular platform that joins the two flights of a 180° stair. Deeper than the square landing of a quarter-turn, because the body actually turns about.
Newel
The post or core the winders radiate from. Its radius sets the inner going and, on the winder tab, the well between flights.
Going
The horizontal distance from one nosing to the next. It is the foot's landing, not the depth of the board (which includes the nosing overhang).
Walking line
The path actually walked. About 500 mm from the inner string once the flight is a metre or more wide; on centre below that. Winder going is judged on this line.
Winder
A tapered tread that pivots around the newel so the stair can turn without a landing. Going grows with radius: pinched at the post, comfortable on the walking line, wide at the wall.
2R+G
Twice the rise plus the going. Approved Document K wants this between 550 and 700 mm for a private stair. The same idea as Blondel's 63–64 cm, in millimetres.
String
The pitched member that carries the treads (closed string, cut string, central string). In a U, the two inner strings face each other across the well.
Headroom
Clear height from nosing to soffit, measured plumb. In a new dwelling, Approved Document K looks for 2.0 m. On a U it is judged on the upper flight, not at the newel.

Related calculators